An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy
نویسندگان
چکیده
Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converted into an I-125 LDR equivalent DU(20) in order to use the urethral NTCP model. Second, the propagation of uncertainties through the steps in the NTCP calculation was assessed in order to identify the parameters responsible for large data uncertainties. Two sets of radiobiological parameters were studied. The NTCP results all fall in the 19%-23% range and are associated with large uncertainties, making the comparison difficult. Depending on the dataset chosen, the ranking of NTCP values among the six seed implants studied changes. Moreover, the large uncertainties on the fitting parameters of the urethral NTCP model result in large uncertainty on the NTCP value. In conclusion, the use of NTCP model for permanent brachytherapy is feasible but it is essential that the uncertainties on the parameters in the model be reduced.
منابع مشابه
Comparison of IPSA and HIPO inverse planning optimization algorithms for prostate HDR brachytherapy
Publications have reported the benefits of using high-dose-rate brachytherapy (HDRB) for the treatment of prostate cancer, since it provides similar biochemical control as other treatments while showing lowest long-term complications to the organs at risk (OAR). With the inclusion of anatomy-based inverse planning opti- mizers, HDRB has the advantage of potentially allowing dose escalation. Amo...
متن کاملInvestigating the Longitudinal Optical Conductivity in Three-Layer Graphene Systems with Composes Mono-Bi-Bi and Bi-Mono-Bi and Bi-Bi-Mono
The longitudinal optical conductivity is the most important property for graphene-baseddevices. So investigating this property for spatially separated few-layer graphene systems analytically and numerically is the main purpose of our study. Each layer can be mono- or bi-layer graphene. The density-density correlation function has been screened by the dielectric function using the random p...
متن کاملMono-Mono-Mono and Bi-Bi-Bi three-layer graphene systems’ optical conductivity
Investigating the longitudinal optical conductivity of graphene systems, which is the mostimportant property for opto-electronic devices, for three-layer graphene systems theoretically and numerically is the main purpose of this study. Each layer can be mono- or bi-layer graphene. Separation between layers has been denoted by d, selected to be about ten nanometers. The carrier densities i...
متن کاملA Brachytherapy Plan Evaluation Tool for Interstitial Applications
Radiobiological metrics such as tumor control probability (TCP) and normal tissue complication probability (NTCP) help in assessing the quality of brachytherapy plans. Application of such metrics in clinics as well as research is still inadequate. This study presents the implementation of two indigenously designed plan evaluation modules: Brachy_TCP and Brachy_NTCP. Evaluation tools were constr...
متن کاملSalvage brachytherapy for local recurrences of prostate cancer treated previously with radiotherapy
PURPOSE The aim of the study was to analyze early effects and toxicity of salvage high dose rate brachytherapy for local recurrences of adenocarcinoma of the prostate after external beam radiotherapy (EBRT). MATERIAL AND METHODS In MCS Memorial Institute of Oncology in Gliwice a research programme on salvage HDR brachytherapy for local recurrences of prostate cancer treated previously with EB...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2011 شماره
صفحات -
تاریخ انتشار 2011