Blood gas analysis: effect of air bubbles in syringe and delay in estimation.

نویسندگان

  • C K Biswas
  • J M Ramos
  • B Agroyannis
  • D N Kerr
چکیده

Two common sources of error in blood pH and blood gas analysis were studied. The effect of delay in estimation was studied in 10 volunteers and 40 patients. Syringes were stored at 0 degree C, (crushed ice), 4 degrees C (refrigerator) and 22 degrees C (room temperature). The pressure of oxygen (PO2) fell significantly by 20 minutes at 4 degrees C and 22 degrees C but did not change significantly at 0 degree C for up to 30 minutes. Blood pH, pressure of carbon dioxide (PCO2), and base excess did not change significantly for up to 30 minutes at 4 degrees C and 22 degrees C and up to 60 minutes at 0 degrees C. The effect of air bubbles in the syringe was studied by leaving a single bubble or froth in contact with the blood for one to five minutes in 40 patients. Po2 rose significantly after two minutes' contact with froth and two minutes' contact with the air bubble, and PCO2 fell significantly after three minutes' contact with the air bubble. Size of the bubble had little effect on rates of change. Blood pH, bicarbonate, TCO2, and base excess did not change significantly after up to five minutes' contact. For accurate estimation of PO2 and PCO2 it is necessary to avoid frothing, to expel all air bubbles within two minutes, and to inject the sample into the machine within 10 minutes or store the syringe in crushed ice. The requirements for blood pH and base excess measurement are less exacting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air bubbles and temperature effect on blood gas analysis.

The effect of temperature, time of storage, and presence of air bubbles in specimens for blood gas analysis was studied. The results show that air bubbles in a 10% proportion are undesirable because of significant elevation in the PO2, and the storage of anaerobic blood samples at room temperature (25 degrees C) is acceptable when measurements are done within the first 20 minutes.

متن کامل

Numerical Analysis of Water and Air in Venturi Tube to Produce Micro-Bubbles

Two-phase flow regimes are affected by conduit position, alignment, geometry, flow direction, physical characteristics, and flow rate of each phase as well as the heat flux toward the boundaries. Due to the importance of two-phase flow, numerous regimes have been identified. The first step in studying micro-bubble formation inside a venturi tube is to recognize the type of flow regimes. In this...

متن کامل

Effect of air column in transport canisters on measured gas contents of coal

Canister desorption is a widely used technique to measure the gas content of coal. The gas content data, when normalized to volume/weight and multiplied by coal seam mass, is used to estimate the gas in place in an area around the cored hole. However, the gas content and the percentage of each constituent are likely to be influenced by trapped air in the canister at the time of the coal enclosu...

متن کامل

Effect of Seawater on Micro-Nano Air Bubbles Concrete for Repair of Coastal Structures

This paper investigated the effects of seawater curing of concrete made by Micro-Nano Air Bubbles (MNAB) on compressive, flexural and tensile strengths of the concrete. This product will be applicable for rehabilitation or repair of coastal RC structures. In this research, the effect of different combinations of concrete ingredients including 0-100, 25-75, 50-50, 75-25, and 100-0 percent ...

متن کامل

Experimental Study of Heat Transfer Rate in a Shell and Tube Heat Exchanger with Air Bubble Injection (TECHNICAL NOTE)

Shell and tube heat exchangers are widely being used in many of industrial and power engineering applications. Different techniques have been employed in order to enhance the performance of the heat exchanger. Air bubble injection is one method to increase the turbulence of the flowing fluids which in turn enhance the heat transfer performance. Injecting air bubbles is one of the promising tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 285 6355  شماره 

صفحات  -

تاریخ انتشار 1982