Temperature changes in dental implants following exposure to hot substances in an ex vivo model.

نویسندگان

  • Osnat Feuerstein
  • Kobi Zeichner
  • Chen Imbari
  • Zeev Ormianer
  • Nachum Samet
  • Ervin I Weiss
چکیده

OBJECTIVES The habitual consumption of extremely hot foods and beverages may affect implant treatment modality. Our objectives were to: (i) establish the maximum temperature produced intra-orally while consuming very hot substances and (ii) use these values in an ex vivo model to assess the temperature changes along the implant-bone interface. MATERIALS AND METHODS Temperatures were measured using thermocouples linked to a computer. The thermocouple electrodes were attached to the tooth-gum interface of the interproximal areas in 14 volunteers during consumption of extremely hot foods and beverages. The in vivo measured temperature values obtained were used in an ex vivo model of a bovine mandible block with an implant and with an assembled abutment. Temperatures were measured by thermocouple electrodes attached to five locations, three of them along the implant-bone interface. RESULTS During consumption of a hot beverage, a maximum temperature of up to 76.3 degrees C was recorded, and a calculated extreme intra-oral temperature of 61.4 degrees C was established. The ex vivo model showed a high correlation between the temperature measured at the abutment and that measured at the abutment-implant interface and inside the implant, reaching maximum temperatures close to 60 degrees C. At the mid-implant-bone and apical implant-bone interfaces, the maximum temperatures measured were 43.3 and 42 degrees C, respectively. CONCLUSIONS The maximum temperatures measured at the implant-bone interfaces reached the temperature threshold of transient changes in bone (42 degrees C). The results of this study support the notion that intra-oral temperatures, developed during the consumption of very hot substances, may be capable of damaging peri-implant tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اثر تغییرات دمایی محیط د‌هان در جریان مصرف مواد نوشیدنی سرد و گرم بر دمای ایمپلنت

  Background and Aims: Thermal changes in the oral cavity can be transferred to the implants placed in bone and affect the prognosis of the treatments. Furthermore, some investigators proposed improvement of habitual consumption of hot or cold beverages. The aim of the present study was to measure the effect of temperature changes in the oral cavity following consumption of hot and cold drinks ...

متن کامل

Thermal and Surface Changes of Dental Implants Following Use of Rotary Instruments and Piezoelectric Devices for Implantoplasty: An In-Vitro Study

  Objective: Peri-implantitis is an irreversible inflammatory reaction in the soft and hard tissues around a functional implant . One of the treatment approaches of this disease include smoothing and polishing the rough surface and removing threads on the implants using rotary instruments, which is called implantoplasy. Clinicians should perform implantoplasty with caution because it may raise ...

متن کامل

Colorimetric Comparison of Tooth Color Change Following the Use of Two Endodontic Sealers: An Ex-Vivo Study

Background and Aim: Tooth discoloration induced by endodontic sealers is an un-desired outcome of endodontic treatment that affects the esthetic appearance of the teeth, which is important especially in the anterior region. The aim of the present study was to compare the coronal discoloration caused by two frequently used resin-based sealers namely EasySeal and AdSeal. Materials and Methods: F...

متن کامل

Study of Changes in Some Pathophysiological Stress Markers in Different Age Groups of an Animal Model of Acute and Chronic Heat Stress

This study demonstrates the changes in six different pathophysiological parameters such as body weight, body temperature, fecal pellet count, blood-brain barrier (BBB) permeability, plasma corticosterone level and emergence of hemorrhagic peptic ulcer spots due to exposure to high environmental heat in three different age groups of freely moving rats. Methods: Each age group of rats was sub di...

متن کامل

Evaluation of heat conduction in dental implants after exposure to hot beverages.

STATEMENT OF PROBLEM It is unknown if the consumption of hot beverages after implant placement poses a danger of overheating at the bone-implant interface. PURPOSE The purpose of this study was to investigate the effect of simulated consumption of hot beverages on the heat transfer to different dental implant types, implant sizes, and the presence of an interim restoration. MATERIAL AND MET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2008