چکیده

A surface electromyogram (EMG), which measures a voltage waveform produced by skeletal muscles on skin, is an important tool for applications detecting the human will of motion, such as for prosthetic hands and prosthetic legs. In the application to a prosthetic hand, a multipoint EMG measurement is required to precisely control the hand [1, 2]. Conventional multipoint measurements with a passive electrode array [1-3], however, have two problems: 1) Measurement over a long time period is annoying, because the EMG electrodes placed on the skin are rigid, and 2) the signal integrity of EMG is degraded, because the number of wires between the electrodes and the front-end circuits increases with increasing number of measurement points. To address these challenges, a surface EMG measurement sheet (SEMS) on which an EMG electrode array and a front-end amplifier array with 2V organic transistors are integrated on a 1μm-thick ultra-flexible film is developed to control prosthetic hands. The developed SEMS enables a comfortable long-time measurement without signal integrity degradation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization and Design of Organic Field-Effect Transistor Circuits for Sensing Bioelectromagnetism NSF Summer Undergraduate Fellowship in Sensor Technologies

Current scanning technology for the brain and heart requires electrodes to be placed on the surface, with a wire connected to each electrode. Because the electrodes are large, it is impossible to achieve a high sampling resolution of the signals from the tissue being scanned. Silicon based structures are not very suitable for this application. They have a rigid planar surface which prevents the...

متن کامل

Towards a Hand Gestures Recognition Using Weak and a Single-channel Surface Emg Signals

This article presents a method to obtain a myoelectric control system for hand prosthesis with individual fingers, wrist flexion/extension and grasp movements, based on weak surface electromyogram (sEMG) recorded from the forearm, both able-bodied and amputees. This study aims to a reduced-channel scheme (a single sEMG channel) for hand patterns discrimination. A combination of commonly used fe...

متن کامل

sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand

One of the greatest challenges of using a myoelectric prosthetic hand in daily life is to conveniently measure stable myoelectric signals. This study proposes a novel surface electromyography (sEMG) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy electrodes) to allow people with disabilities to control prosthetic limbs. The PPy electrodes are sewn on an elastic band to ...

متن کامل

Organic Thin Film Transistors with Polyvinylpyrrolidone / Nickel Oxide Sol-Gel Derived Nanocomposite Insulator

Polyvinylpyrrolidone  /  Nickel  oxide  (PVP/NiO)  dielectrics  were fabricated  with  sol-gel  method  using  0.2  g  of  PVP  at  different working  temperatures  of  80,  150  and  200  ºC.  Structural  properties and surface morphology of the hybrid films were investigated by X- Ray  diffraction  (XRD)  and  Scanning  Electron Microscope  (SEM) respectively. Energy dispersive X-ray spec...

متن کامل

Nano Organic Transistor with SiO2 / Poly VinylPyrrolidone Dielectric

In this paper, the morphology, roughness and nano structural properties of SiO2/Poly Vinyl Pyrrolidone  synthesized with sol gel method,  characterized by using scanning electron microscopy, atomic force microscopy and GPS132A techniques.The main material taken from oxide silicon with weight percentage of 20, 40, 60, 80 and from poly vinyl pyrrolidone with percentages of 80, 60, 40, 20 is synth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013