Dual chamber pacing mode in an atrial antitachycardia pacing device without a ventricular lead - A necessary evil.

نویسندگان

  • Amit Noheria
  • Paul A Friedman
  • Samuel J Asirvatham
  • Christopher J McLeod
چکیده

We present a case of a single chamber atrial pacemaker implanted for sinus node dysfunction and treatment of macroreentrant atrial tachycardias with atrial antitachycardia pacing. The patient presented with sustained atrial tachycardia above the detection rate, however, the device was unable to detect the tachycardia and did not deliver the programmed therapy. We discuss the nuances of the atrial tachyarrhythmia detection algorithms, and the programming strategies to maximize detection of atrial arrhythmias in a single chamber atrial pacemaker.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of pacing mode in the development of atrial fibrillation.

Asynchronous ventricular pacing has been shown to increase the risk of development of atrial fibrillation (AF) because of various mechanisms: retrograde atrioventricular (AV) conduction with increase in atrial pressure causing acute atrial stretch and reverse flow in the pulmonary veins, mitral regurgitation, reduced coronary blood flow, adverse neuroendocrine reactions, etc. Dual-chamber pacin...

متن کامل

Role of permanent pacing to prevent atrial fibrillation: science advisory from the American Heart Association Council on Clinical Cardiology (Subcommittee on Electrocardiography and Arrhythmias) and the Quality of Care and Outcomes Research Interdisciplinary Working Group, in collaboration with the Heart Rhythm Society.

This advisory summarizes the current database on pacing modalities and algorithms used to prevent and terminate atrial fibrillation (AF). On the basis of the evidence indicating that ventricular pacing is associated with a higher incidence of AF in patients with sinus node dysfunction, a patient who has a history of AF and needs a pacemaker for bradycardia should receive a physiological pacemak...

متن کامل

An unusual ICD shock: What is the mechanism?

Case report A 48-year-old man with nonischemic dilated cardiomyopathy, left ventricular ejection fraction r35% status post dual-chamber ICD (Boston Scientific Energen, model E142) since September 2012, history of ventricular tachycardia with antitachycardia pacing (ATP) therapy, paroxysmal atrial fibrillation, and atrial tachycardia on beta-blocker therapy was seen in clinic following an ICD sh...

متن کامل

Initiation of ventricular tachycardia by interruption of pacemaker-mediated tachycardia in a patient with a dual-chamber implantable cardioverter defibrillator.

A 74-year-old man with a dual-chamber implantable cardioverter defibrillator implanted 3 years before experienced multiple ventricular tachycardias (VTs). All episodes were initiated by pacemaker-mediated tachycardia (PMT) that was either stopped by atrial undersensing or the tachycardia termination algorithm of the device. After the termination of PMT, two rapid ventricular paced beats, the fi...

متن کامل

A combined atrial/ventricular lead for permanent dual-chamber cardiac pacing applications.

A new urethane insulated dual unipolar atrial/ventricular transvenous lead has been developed to facilitate implantation of permanent dual-chamber cardiac pacing systems in man. The atrial portion of the lead has tines and is designed to retain a permanent J configuration, while the coaxially situated ventricular lead is freely and independently adjustable and incorporates a ring tip electrode ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian pacing and electrophysiology journal

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2015