Effect of trephination technique on the ultrastructure of corneal transplants: guided trephine system v posterior punch technique.
نویسندگان
چکیده
AIM Different trephination methods may lead to differences in degree of tissue damage and endothelial cell loss, which both influence the outcome of penetrating keratoplasty. Light, transmission, and scanning electron microscopy were used to compare the ultrastructural appearance of the cut edges and the endothelial cell loss in 26 human corneal donor buttons obtained by trephination with the suction fixated guided trephine system (GTS) and with the free hand posterior punch technique (PPT). METHODS Human corneas were stored between 5 and 14 days in Optisol. One cornea from each pair was used for each technique. Trephinations (7.5 mm) were performed either from the anterior direction with the GTS (n=13) or from the posterior direction with the PPT (n=13) using Pharmacia Superblade trephines. Light microscopy, transmission electron, and scanning electron microscopy were performed according to standard procedures. Widening of the cut edges and the extent of endothelial cell loss were measured at three different areas per corneal button and analysed statistically. RESULTS In contrast with the PPT, the GTS trephine produced considerable fibrillar disorder at the cut edges of the corneal buttons. The distance to which the endothelial cell loss extended from the edges of the cuts was significantly (p<0. 001) lower for the GTS (42.2 (SD 50.8) microm from the edge) than for the PPT (109.3 (68.1) microm). Stromal widening at the edges (measured as percentage increase in stromal thickness, compared with the thickness of the central cornea) was observed with both techniques. However, the mean stromal widening produced by the GTS was significantly greater than that produced by PPT (106% (24%) v 69% (21%); p<0.002). CONCLUSION Both trephination techniques produced only minor tissue damage. Nevertheless, there were distinct differences in the fine appearance of the cuts produced by the GTS and the PPT techniques. The extent of the fibrillar dislocation and stromal widening was greater at the edges of the GTS buttons. The GTS technique produced significantly less endothelial cell loss at the cut edges than did the free hand punching technique, PPT.
منابع مشابه
EVect of trephination technique on the ultrastructure of corneal transplants: guided trephine system v posterior punch technique
Aim—DiVerent trephination methods may lead to diVerences in degree of tissue damage and endothelial cell loss, which both influence the outcome of penetrating keratoplasty. Light, transmission, and scanning electron microscopy were used to compare the ultrastructural appearance of the cut edges and the endothelial cell loss in 26 human corneal donor buttons obtained by trephination with the suc...
متن کاملComparison of Hanna and Hessburg-Barron trephine and punch systems using histological, anterior segment optical coherence tomography, and elliptical curve fitting models
BACKGROUND This study analyzes the characteristics of donor and recipient tissue preparation between the Hessburg-Barron and Hanna punch and trephine systems by using elliptical curve fitting models, light microscopy, and anterior segment optical coherence tomography (AS-OCT). METHODS Eight millimeter Hessburg-Barron and Hanna vacuum trephines and punches were used on six cadaver globes and s...
متن کاملAccuracy of corneal trephination depth using the Moria single-use adjustable depth vacuum trephine system
BACKGROUND The Moria single-use adjustable depth trephine is a device that allows a goal trephination depth to be set prior to the surgical procedure. METHODS Eleven fresh human cadaveric eyes were trephined using 8.0 mm Moria single-use adjustable vacuum trephines. Prior to trephination, the average corneal pachymetry in the peripheral 7-10 mm range was obtained using anterior segment optica...
متن کاملDonor cornea preparation in partial big bubble deep anterior lamellar keratoplasty
BACKGROUND The purpose of this paper is to describe a technique of donor cornea preparation to ensure good graft-host apposition in incomplete big bubble deep anterior lamellar keratoplasty. METHODS Following a partial-thickness trephination, manual dissection and excision of corneal stroma was performed. Anwar's big-bubble technique involving a deep stromal air injection was then initiated. ...
متن کاملPenetrating Keratoplasty for Keratoconus – Excimer Versus Femtosecond Laser Trephination
BACKGROUND In case of keratoconus, rigid gas-permeable contact lenses as the correction method of first choice allow for a good visual acuity for quite some time. In a severe stage of the disease with major cone-shaped protrusion of the cornea, even specially designed keratoconus contact lenses are no more tolerated. In case of existing contraindications for intrastromal ring segments, corneal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 83 10 شماره
صفحات -
تاریخ انتشار 1999