Comparison of forceps used for transbronchial lung biopsy. Bigger may not be better.

نویسندگان

  • L S Smith
  • M Seaquist
  • R F Schillaci
چکیده

Transbronchial lung biopsy is a useful procedure to obtain an alveolar specimen in the evaluation of diffuse lung infiltrates. Large forceps (cup and alligator) are expected to result in larger specimens and improve diagnostic yield. We performed transbronchial lung biopsy in 20 patients using two different sized forceps in each patient. We compared the histology and histopathologic diagnoses obtained by small cup forceps, large cup forceps, and large alligator forceps. Small and large cup forceps provided equally good results; however, the large open end of the alligator forceps often prevented distal passage through narrowing airways, engaging proximal bifurcating bronchial wall and cartilage rather than lung parenchyma. Small and large cup forceps are more likely to obtain the desired alveolar specimen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE DIAGNOSTIC YIELD OF TRANSBRONCHIAL LUNG BIOPSY IN DIFFUSE INFILTRATIVE PULMONARY DISEASES BY PLAIN CUP FORCEPS. A STUDY OF 54 CASES IN IRAN

The technique of transbronchial lung biopsy (TBLB) has expanded the diagnostic yield of bronchoscopy . In this article we are presenting 54 patients with diffuse pulmonary parenchymal involvement who underwent this procedure during six years between June 1980 and December 1989. The diagnostic yield of this technique in diffuse pulmonary parenchymal disease is great and was 66 percent exclu...

متن کامل

Diagnostic Yield and Safety of Cryoprobe Transbronchial Lung Biopsy in Diffuse Parenchymal Lung Diseases: Systematic Review and Meta-Analysis.

BACKGROUND Transbronchial lung biopsy with flexible forceps is the most commonly used technique in diagnosis of diseases diffusely involving the lung parenchyma. Recently, transbronchial lung biopsy using the flexible cryoprobe (cryo-transbronchial lung biopsy) has also been reported. Herein, we perform a systematic review and meta-analysis describing the efficacy and safety of cryo-transbronch...

متن کامل

Familial spontaneous pneumothorax: importance of screening for renal tumours.

We thank G.L. Casoni and V. Poletti for their comments regarding our study showing the diagnostic utility of a thin bronchoscope with a 1.7-mm working channel for peripheral pulmonary lesions [1]. Their main quarrel with a channel of this size is its possible inability to control bleeding, and they argue that larger forceps are better than smaller ones in terms of diagnostic yield. Bleeding is ...

متن کامل

Comparison of transbronchial lung biopsy yield between standard forceps and electrocautery hot forceps in swine.

BACKGROUND Transbronchial lung biopsy (TBLB) is a commonly performed bronchoscopic procedure. Previous studies have suggested that larger biopsy forceps may improve diagnostic yield; however, the risk of bleeding associated with larger samples may be increased. The hot forceps are large forceps that are connected to an electrocautery system to minimize bleeding at the time of biopsy. OBJECTIV...

متن کامل

Lung rejection after transplantation.

With the introduction of Cyclosporine as an immunosuppressive agent, combined heart and lung transplantation (HLTx) became an effective treatment for severe pulmonary vascular disease [1] and has been extended successfully to treat end-stage lung disease [2] and cystic fibrosis [3, 4]. Single lung transplantation offers a treatment for cryptogenic fibrosing alveolitis [5]. It was initially beli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 87 5  شماره 

صفحات  -

تاریخ انتشار 1985