Automated enzymic measurement of total cholesterol in serum.

نویسندگان

  • G S Rautela
  • R J Liedtke
چکیده

We describe a completely automated enzymic system for measuring total cholesterol in serum. All reagents are contained in an analytical test pack and the test is performed on Du Pont's Automatic Clinical Analyzer (aca), which mixes the sample (20 microliter) and reagents and performs the necessary absorbance measurements and calculations. In the procedure, cholesterol oxidase oxidizes free cholesterol. The oxidation step produces cholest-4-en-3-one and hydrochloride peroxidesterase hydrolyzes cholesterol esters and cholesterol in direct proportion to the amount of cholesterol present. N,N-Diethylaniline hydrochloride and 4-aminoantipyrine react with the hydrogen peroxide to produce a quinoneimine dye (lambda max = 553 nm). Interacting reagents have been optimized simultaneously (coöptimization) utilizing response surface designs coupled with computer analysis of the data. Reagent efficiency is high and analytical performance reliable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of cholesterol oxidase for assay of total and free cholesterol in serum by continuous-flow analysis.

Idescribe an assay for total cholesterol in serum, with use of the AutoAnalyzer ii (Technicon), in which cholesterol esters are saponified by alkali, cholesterol is held in aqueous micellar solution with a surfactant (Triton X-100) and oxidized by cholesterol oxidase, and the hydrogen peroxide produced is measured by chelation with Ti4+ and xylenol orange. An assay for free cholesterol in serum...

متن کامل

Influence of incomplete cholesteryl ester hydrolysis on enzymic measurements of cholesterol.

Esterolytic activity of three enzymic cholesterol reagents was evaluated with use of human serum-based reference materials. Primary cholesterol standards were used to calibrate the enzymic methods, and incomplete cholesteryl ester hydrolysis was measured as the bias between the enzymic cholesterol values and corresponding reference values. The average biases observed with eight reference specim...

متن کامل

High-density-lipoprotein cholesterol in heparin-MnCl2 supernates determined with the Dow enzymic method after precipitation of Mn2+ with HCO3-.

Manganese interferes with enzymic cholesterol methods. In this study, we enzymically measured high-density-lipoprotein (HDL) cholesterol in heparin-Mn2+ supernates that had been treated with NaHCO3 (91 mmol/L) to precipitate Mn2+, and compared results with those by an automated Liebermann- Burchard method. For untreated supernates of 96 fresh plasma samples, the enzymic values were 10.4% higher...

متن کامل

Enzymic serum cholesterol measurement with a basic autoanalyzer and Du Pont aca method.

I compared enzymic methods for total serum cholesterol as used with discrete (Du Pont aca and reagent packs) and continuous-flow (Boehringer Mannheim reagents and the Technicon AuotAnalyzer I) analysis of normal, icteric, and lipemic sera. The regression equation for 24 clear, non-icteric sera was: y (continuous flow) = 0.944x (aca) + 10.69; r = 0.971, Syx +/- 53.7 mg of cholesterol per liter. ...

متن کامل

Suitability of various control sera for use in testing the accuracy of cholesterol determination with enzymic kits.

We used 20 different commercial enzymic kits to measure cholesterol in 19 commercial control sera and in a pooled specimen of human serum and compared the relative biases, with the Abell -Kendall procedure as reference. Our purpose was to select those sera in various enzymic kits showing behavior similar to that of human serum and which thus can be used to measure the accuracy of these kits. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 1978