Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review
نویسندگان
چکیده
INTRODUCTION Glucose control to prevent both hyperglycemia and hypoglycemia is important in an intensive care unit. Arterial blood gas analyzers and glucose meters are commonly used to measure blood-glucose concentration in an intensive care unit; however, their accuracies are still unclear. METHODS We performed a systematic literature search (January 1, 2001, to August 31, 2012) to find clinical studies comparing blood-glucose values measured with glucose meters and/or arterial blood gas analyzers with those simultaneously measured with a central laboratory machine in critically ill adult patients. RESULTS We reviewed 879 articles and found 21 studies in which the accuracy of blood-glucose monitoring by arterial blood gas analyzers and/or glucometers by using central laboratory methods as references was assessed in critically ill adult patients. Of those 21 studies, 11 studies in which International Organization for Standardization criteria, error-grid method, or percentage of values within 20% of the error of a reference were used were selected for evaluation. The accuracy of blood-glucose measurements by arterial blood gas analyzers and glucose meters by using arterial blood was significantly higher than that of measurements with glucose meters by using capillary blood (odds ratios for error: 0.04, P<0.001; and 0.36, P<0.001). The accuracy of blood-glucose measurements with arterial blood gas analyzers tended to be higher than that of measurements with glucose meters by using arterial blood (P=0.20). In the hypoglycemic range (defined as <81 mg/dl), the incidence of errors using these devices was higher than that in the nonhypoglycemic range (odds ratios for error: arterial blood gas analyzers, 1.86, P=0.15; glucose meters with capillary blood, 1.84, P=0.03; glucose meters with arterial blood, 2.33, P=0.02). Unstable hemodynamics (edema and use of a vasopressor) and use of insulin were associated with increased error of blood glucose monitoring with glucose meters. CONCLUSIONS Our literature review showed that the accuracy of blood-glucose measurements with arterial blood gas analyzers was significantly higher than that of measurements with glucose meters by using capillary blood and tended to be higher than that of measurements with glucose meters by using arterial blood. These results should be interpreted with caution because of the large variation of accuracy among devices. Because blood-glucose monitoring was less accurate within or near the hypoglycemic range, especially in patients with unstable hemodynamics or receiving insulin infusion, we should be aware that current blood glucose-monitoring technology has not reached a high enough degree of accuracy and reliability to lead to appropriate glucose control in critically ill patients.
منابع مشابه
Relative accuracy of arterial and capillary glucose meter measurements in critically ill patients.
AIM As optimizing glucose control in critically ill patients remains a challenge for intensive-care physicians, this study aimed to determine the accuracy of glucose measurements. METHODS The accuracy of capillary and arterial blood glucose meter measurements was compared with central laboratory arterial glucose measurements; the factors associated with inaccurate measures were also determine...
متن کاملPoint accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study
INTRODUCTION There is a need for continuous glucose monitoring in critically ill patients. The objective of this trial was to determine the point accuracy and reliability of a device designed for continuous monitoring of interstitial glucose levels in intensive care unit patients. METHODS We evaluated point accuracy by comparing device readings with glucose measurements in arterial blood by u...
متن کاملThe performance of flash glucose monitoring in critically ill patients with diabetes.
OBJECTIVE Frequent glucose monitoring may improve glycaemic control in critically ill patients with diabetes. We aimed to assess the accuracy of a novel subcutaneous flash glucose monitor (FreeStyle Libre [Abbott Diabetes Care]) in these patients. METHODS We applied the FreeStyle Libre sensor to the upper arm of eight patients with diabetes in the intensive care unit and obtained hourly flash...
متن کاملIntensive insulin therapy in critically ill hospitalized patients: making it safe and effective.
Intensive insulin therapy (IIT) for hyperglycemia in critically ill patients has become a standard practice. Target levels for glycemia have fluctuated since 2000, as evidence initially indicated that tight glycemic control to so-called normoglycemia (80-110 mg/dl) leads to the lowest morbidity and mortality without hypoglycemic complications. Subsequent studies have demonstrated minimal clinic...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کامل