Comparative evaluation of three interfaces for non-invasive ventilation: a randomized cross-over design physiologic study on healthy volunteers

نویسندگان

  • Rosanna Vaschetto
  • Audrey De Jong
  • Matthieu Conseil
  • Fabrice Galia
  • Martin Mahul
  • Yannael Coisel
  • Albert Prades
  • Paolo Navalesi
  • Samir Jaber
چکیده

INTRODUCTION Interface choice is crucial for non-invasive ventilation (NIV) success. We compared a new interface, the helmet next (HN), with the facial mask (FM) and the standard helmet (HS) in twelve healthy volunteers. METHODS In this study, five NIV trials were randomly applied, preceded and followed by a trial of unassisted spontaneous breathing (SB). Baseline settings, for example, 5 cmH2O of both inspiratory pressure support (PS) and positive end-expiratory pressure (PEEP), were applied through FM, HS and HN, while increased settings (PS and PEEP of 8 cmH2O) were only applied through HS and HN. We measured flow, airway, esophageal and gastric pressures, and calculated inspiratory effort indexes and trigger delays. Comfort was assessed with a visual-analog-scale. RESULTS We found that FM, HS and HN at baseline settings were not significantly different with respect to inspiratory effort indexes and comfort. Inspiratory trigger delay and time of synchrony (TI,synchrony) were significantly improved by FM compared to both helmets, whereas expiratory trigger delay was shorter with FM, as opposed to HS only. HN at increased settings performed better than FM in decreasing inspiratory effort measured by pressure-time product of transdiaphragmatic pressure (PTPdi)/breath (10.7 ± 9.9 versus 17.0 ± 11.0 cmH2Os), and PTPdi/min (128 ± 96 versus 204 ± 81 cmH2Os/min), and PTPdi/L (12.6 ± 9.9 versus 30.2 ± 16.8 cmH2Os/L). TI, synchrony was inferior between HN and HS at increased settings and FM. CONCLUSIONS HN might hold some advantages with respect to interaction and synchrony between subject and ventilator, but studies on patients are needed to confirm these findings. TRIAL REGISTRATION ClinicalTrials.gov NCT01610960.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Bioavailability of Ranitidine Tablets in Healthy Volunteers

The pharmacokinetic parameters of domestic and imported ranitidine hydrochloride tablets (Ranitidine, formulated and manufactured by Kharazmi Pharmaceuticals, Iran, and Zantac ? manufactured by Glaxo, UK) were measured in 14 healthy subjects following oral administration of a single 300-mg dose of each brand and compared for bioequivalence evaluation. The pharmaceutical equivalency of both fo...

متن کامل

Comparative Bioavailability of Ranitidine Tablets in Healthy Volunteers

The pharmacokinetic parameters of domestic and imported ranitidine hydrochloride tablets (Ranitidine, formulated and manufactured by Kharazmi Pharmaceuticals, Iran, and Zantac ? manufactured by Glaxo, UK) were measured in 14 healthy subjects following oral administration of a single 300-mg dose of each brand and compared for bioequivalence evaluation. The pharmaceutical equivalency of both fo...

متن کامل

Comparison of Nasal Non-invasive Ventilation Methods in Preterm Neonates with Respiratory Distress Syndrome

Background: Humidified heated high flow nasal cannula (HHHFNC), nasal continuous positive airway pressure (NCPAP), and nasal intermittent positive pressure ventilation (NIPPV) are three nasal non-invasive ventilation methods. The purpose of this study was to compare these three methods in decreasing intubation and mechanical ventilation rate in preterm neonates with respiratory distress syndrom...

متن کامل

ویبروآرتروگرافی، روشی نوین در تشخیص استئوآرتریت زانو

Vibroarthrography, A Novel Technique in Diagnosis of Knee Osteoarthritis A. Rahimi PhD PT , M.M. Roostayee MSc PT , D. Shahimoridi MSc PT Received: 02/02/06 Sent for Revision: 24/06/06 Received Revised Manuscript: 27/11/06 Accepted: 26/12/06 Background and Objective: Use of joint sound signals for diagnosis of knee joint disorders has been greatly welcomed since it is a non-invasive and inexpen...

متن کامل

Comparative Bioavailability of Two Tablet Formulations of Dipyridamole in Healthy Volunteers

The bioavailability of two dipyridamol tablet formulations of (Dipyridamole from Tolidaru and Persantin from Boehringer) was compared in 14 healthy male volunteers who received a single dose of 25 mg of the test (T) and the reference (R) products in a randomized balanced 2-way crossover design. Plasma samples were obtained over a 16 h interval and dipyridamole concentrations determined by HPLC ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2014