Stability of the input-output properties of chronically implanted multiple contact nerve cuff stimulating electrodes.

نویسندگان

  • W M Grill
  • J T Mortimer
چکیده

The objective of this investigation was to measure the input-output (I-O) properties of chronically implanted nerve cuff electrodes. Silicone rubber spiral nerve cuff electrodes, containing 12 individual platinum electrode contacts, were implanted on the sciatic nerve of seven adult cats for 28-34 weeks. Measurements of the torque generated at the ankle joint by electrical stimulation of the sciatic nerve were made every 1-2 weeks for the first 6 weeks post-implant and every 3-5 weeks between 6 weeks and 32 weeks post-implant. In three implants the percutaneous lead cable was irreparably damaged by the animal within 4 weeks after implant and further testing was not possible. One additional lead cable was irreparably damaged by the animal at 17 weeks post-implant. The three remaining implants functioned for 28, 31, and 32 weeks. Input-output curves of ankle joint torque as a function of stimulus current amplitude were repeatable within an experimental session, but there were changes in I-O curves between sessions. The degree of variability in I-O properties differed between implants and between different contacts within the same implant. After 8 weeks, the session to session changes in the stimulus amplitude required to generate 50% of the maximum torque (I50) were smaller (15+/-19%, mean +/- s.d.) than the changes in I50 measured between 1 week and 8 weeks post-implant (34+/-42%). Furthermore, the I-O properties were more stable across changes in limb position in the late post-implant period than in acutely implanted cuff electrodes. These results suggest that tissue encapsulation acted to stabilize chronically implanted cuff electrodes. Electrode movement relative to the nerve, de- and regeneration of nerve fibers, and the inability to precisely reproduce limb position in the measurement apparatus all may have contributed to the variability in I-O properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporal Stability of Nerve Cuf ' F Electrode Recruitment Properties

The recruitment properties of multiple contact nerve cuff electrodes chronically implanted on the cat sciatic nerve were measured, and the week to week variability was documented. The variability in recruitment properties was greatest between 1 week and 8 weeks post-implant. After 8 weeks the session to session changes were significantly smaller than in the early post-implant period. No trends ...

متن کامل

Quantification of recruitment properties of multiple contact cuff electrodes.

Nerve-based stimulating electrodes provide the technology for advancing the function of motor system neural prostheses. The goal of this work was to measure and quantify the recruitment properties of a 12 contact spiral nerve cuff electrode. The cuff was implanted on the cat sciatic nerve trunk, which consists of at least four distinct motor fascicles, and the torque generated at the ankle join...

متن کامل

Conduction studies in peripheral cat nerve using implanted electrodes: III. The effects of prolonged constriction on the distal nerve segment.

Electrophysiological properties were monitored in detail in chronically constricted peripheral nerves by implanted, multicontact nerve cuff electrodes and correlated with morphometric histology in selected cases. The physiological and histological responses in nerve to a range of constricting cuffs of standard sizes were readily graded. The initial response to any significant constriction was a...

متن کامل

Recruitment properties of intramuscular and nerve-trunk stimulating electrodes.

Functionally useful reanimation of paralyzed limbs generally requires reliable, finely graded control of muscle recruitment and force with minimal fatigue. We used force and electromyographic (EMG) recordings in combination with myofibrillar adenosine triphosphatase activity and glycogen depletion analysis to investigate the recruitment properties of intramuscular (IM) and nerve cuff (NC) stimu...

متن کامل

Conduction studies in peripheral cat nerve using implanted electrodes: I. Methods and findings in controls.

Silicone rubber cuff and patch electrodes with multiple contacts were implanted along the sciatic-tibial-plantar nerves in cat for repeated studies of conduction properties of normal peripheral nerve over periods of time. The contacts were used in various combinations for precise localization of changes in conduction velocities and excitability along the extent of normal nerves. In this paper t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 1998