Long-Term Stability of Diffractive Multifocal Intraocular Lenses: Contralateral Comparison between Silicone and Acrylic Materials
نویسندگان
چکیده
Objective: To compare visual function stability between silicone and hydrophobic acrylic materials of diffractive multifocal intraocular lenses (MF-IOLs). Methods: This retrospective study reviewed clinical records of 10 patients who received a silicone MF-IOL in the first eye and hydrophobic acrylic lens in the fellow eye. Intra-individual differences in logMAR corrected distance visual acuity (CDVA) and distance-corrected near visual acuity (DCNVA) were evaluated until 2 years postoperatively. Contrast sensitivity at 1 year was also compared. Results: Age of the patients ranged from 39 to 77 years. There was no statistical difference in the uncorrected distance visual acuities at 2 years, while the uncorrected near visual acuity of the silicone IOL was better (P=0.046). The medians of the CDVA and DCNVA with the silicone MF-IOLs were -0.13 and 0.10 logMAR, respectively, while those with hydrophobic acrylic MF-IOLs were -0.09 and 0.12 logMAR, respectively. No significant difference was found between the two materials (P>0.17). There was no difference in the contrast sensitivity (P>0.11). One eye with the silicone MF-IOL underwent Nd:YAG laser capsulotomy. Conclusions: The differences in the material and fabrication of diffractive MF-IOLs did not influence the longterm visual performance.
منابع مشابه
Silicone-diffractive versus acrylic-refractive supplementary iols: visual performance and manual handling.
PURPOSE To compare visual outcome and manual handling of additional multifocal sulcus-fixated intraocular lenses (IOLs) of different materials and lens concepts. METHODS Visual outcomes after implantation of a monofocal IOL in the capsular bag followed by implantation of a sulcus-fixated multifocal IOL (MIOL) in patients with cataract were assessed. Patients were randomly assigned to receive ...
متن کاملBilateral implantation of asymmetrical diffractive multifocal intraocular lenses.
OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...
متن کاملAdhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study.
AIMS To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between th...
متن کاملComparison of diffractive and refractive multifocal intraocular lenses in presbyopia treatment.
Multifocal intraocular lenses (MFIOL) enable good near and far vision after cataract surgery. Excellent results with cataract patients encouraged ophthalmologists to implant MFIOL after clear lens extraction (CLE). There are two types of MFIOL: diffractive and refractive. In our prospective study we compared clinical outcomes after CLE and bilateral implantation of diffractive (Tecnis Multifoca...
متن کاملBiofilm formation by Staphylococcus epidermidis on intraocular lens material.
PURPOSE To compare biofilm formation by Staphylococcus epidermidis on different intraocular lens (IOL) materials. METHODS The S. epidermidis strains, ATCC 12228 (American Type Culture Collection) and ATCC 35984 (biofilm-producer) were used. Biofilms were cultivated on disks of different IOL materials: silicone, PMMA (polymethylmethacrylate), acrylic, or MPC (2-methacryloyloxyethyl phosphorylc...
متن کامل