On Comparing Two Different Tray-Holding Techniques for Edentulous Maxillary Impressions.
نویسندگان
چکیده
PURPOSE This study compared tissue three-dimensional (3D) displacements during the material setting phase of two maxillary impression tray-holding techniques: clinician manual pressure and patient occlusal pressure. MATERIALS AND METHODS The resultant two maxillary casts for each of 10 edentulous patients were compared using an optical 3D measurement system. RESULTS The junction between the hard and soft palates acted like a rotation center during impression making. The vertical displacements were significantly lower and posteriorly set when the impression was taken with the patient's occlusion, in contrast to being located at the anterior two-thirds during the manual impression technique. CONCLUSION Use of patient's occlusion as a tray-holding technique may be preferred during the material setting phase of maxillary impressions.
منابع مشابه
In Vitro Effect of Vent Size and Spacer Thickness on Pressure Produced during Maxillary Edentulous Impression Making by Different Impression Materials
Background and Aim: Inappropriate transfer of pressure during final impression making in fabrication of complete denture can result in ridge resorption. This study aimed to assess the effect of vent size and spacer thickness on pressure produced during maxillary edentulous impression making by different impression materials in vitro. Materials and Methods: This experimental study was carried...
متن کاملComparison of Different Impression Techniques When Using the All-on-Four Implant Treatment Protocol.
PURPOSE The aim of this in vitro study was to compare the accuracy of two different impression techniques for the All-on-Four implant therapy protocol. MATERIALS AND METHODS An acrylic resin analog for an edentulous maxilla with four internal connection implants (Replace Select, Nobel Biocare) was fabricated according to the All-on-Four protocol. A total of 40 impressions were made with diffe...
متن کامل[Pressures produced in a tray during impression procedures. Maxillary edentulous impressions].
It was previously reported that pressures produced during compression of impression materials between parallel disks were affected by several factors, and that hydrodynamical analyses well characterized the results of experiments. The present study was undertaken to measure and theoretically demonstrate pressure distributions during mechanical impression making of a maxillary edentulous cast an...
متن کاملتعیین دقت ثبت ایمپلنت در دو روش تری باز و تری بسته و تعیین ثبت جزئیات سطح دندان حین این قالبگیری
Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impressio...
متن کامل[Sectional acrylic dentures for a partially edentulous patient with microstomia: a clinical report].
PATIENT The patient was a 48-year-old partially edentulous male with microstomia. His chief complaints were masticatory disturbance and aesthetic problems caused by missing teeth. After trayless impressions for diagnostic casts were made, sectional trays and a sectional record block were used for the definitive impression and maxillomandibular registration. Maxillary and mandibular acrylic sect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of prosthodontics
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2016