Off-bypass implantation of a self-expandable valved stent between inferior vena cava and right atrium.
نویسندگان
چکیده
A glutaraldehyde preserved valved bovine jugular xenograft mounted in a nitinol 'Z' stent, expandable from 7 to 28 mm of internal diameter, was evaluated in vitro (column of water developing a pressure of 45 mmHg and a mock loop including a pulsatile pump) and in vivo in five adult pigs with intra-vascular ultrasound to measure the inferior vena cava diameter via a retroperitoneal access. Through a stent-graft delivery system (24 French) the self expandable valved stent was implanted off-bypass in the inferior vena cava, between hepatic veins and cavo-atrial junction, with flow and pressure gradient recording. The mean length of the valved stent was 22.80+/-1.06 mm, the mean internal diameter 20.97+/-0.5 mm and the mean external diameter 26.67+/-0.9 mm. The valve leaking under pressure was 32.5+/-12.3 ml/min. The mean pressure gradient recorded across the self expandable valved stent implanted in the inferior vena cava was 1.0+/-0.5 mmHg (range 0-2 mmHg). Intra-vascular ultrasound showed partial opening and closing of the valve (mean area reduction from 148.5 to 81.5 mm2), with almost complete occlusion only during deep breaths. The in vitro and in vivo experiments confirmed the feasibility of potential application of the self-expandable valved stent implanted off-bypass in the inferior vena cava for late conversion of failing total cavo-pulmonary connection; intra-vascular ultrasound allows for adequate implantation and evaluation.
منابع مشابه
Multifactorial Neonatal Thrombosis in Inferior Vena Cava Dislodged to the Right Atrium: A Case Report
Background: Neonatal thrombotic diseases can cause mortality or serious morbidity and disability.Case report: In this report, we present a case of neonatal inferior vena cava thromboembolism with several underlyingfactors. Hereditary thrombophilia and genetic mutation in plasminogen activator inhibitor-1 and MTHFR A1298C genesin conjunction with cleft palate resulted in poor l...
متن کاملA new approach to the interventional therapy of tricuspid regurgitation.
Currently, there are no fully developed interventional approaches for the treatment of tricuspid regurgitation (TR). The aim of this study was to evaluate the feasibility of orthotopic interventional placement of a biological prosthetic valve in the tricuspid position by inserting, with a transvenous approach, a self-expandable valve-bearing stent into the right atrium. Based on findings of com...
متن کاملA repositionable valved stent for endovascular treatment of deteriorated bioprostheses.
OBJECTIVES We report our animal experience of endovascular valve replacement (VR) of failed bioprosthesis (BP) using an original delivery catheter allowing repositioning of the valved stent (VS). BACKGROUND Among the different devices designed for percutaneous VR, none has the potential for repositioning of a fully deployed VS. METHODS Five sheep underwent, on beating heart, tricuspid VR wi...
متن کاملICD Leads Extraction and Clearing of Access Way in a Patient With Superior Vena Cava Syndrome
Central vein disease is defined as at least 50% narrowing up to total occlusion of central veins of the thorax including superior vena cava, brachiocephalic, subclavian, and internal jugular vein. Thrombosis due to intravascular leads occurs in approximately 30% to 45% of patients early or late after implantation of a pacemaker by transvenous access.In this case, we report a male patient, 65-ye...
متن کاملTricuspid valved stent implantation: novel stent with a self-expandable super-absorbent polymer.
OBJECTIVE Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve. METHODS A newly designed nitinol stent with SAP was specially designed for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 2 2 شماره
صفحات -
تاریخ انتشار 2003