Abbott ARCHITECT iPhenytoin assay versus similar assays for measuring free phenytoin concentrations.
نویسندگان
چکیده
OBJECTIVE To measure free phenytoin (FP) concentrations in filtered specimens using the Abbott ARCHITECT iPhenytoin assay and to compare results from this method with results from the Abbott TDx/FLx assays. METHODS We verified accuracy, analytic measurement range, and precision for FP measurements. For correlation and therapeutic interval studies, we used filtered calibrators, controls, proficiency-testing materials, and surplus clinical samples. After implementation, we determined proficiency testing results. RESULTS The analytic measurement range was 2.0 to 25.0 micromol/L. Quality control materials (6.1, 12.6, and 20.1 micromol/L) provided mean (SD) recoveries of 96.1 (5.0%), 99.2 (5.0%), and 99.3 (5.7%), respectively, and coefficients of variation of 5.2%, 5.0%, and 5.8%, respectively. Clinical specimens produced mean (SD) FP recovery levels of 103.7 (10.6%) (bias, 0.1 [0.3] micromol/L). Altering the FP therapeutic range (4.0-8.0 micromol/L) was unnecessary. Proficiency testing yielded consistently acceptable results. CONCLUSION Our accuracy, precision, and correlation results were similar for the TDx/FLx and ARCHITECT assays, which demonstrates that the ARCHITECT iPhenytoin assay is acceptable for clinical FP measurements.
منابع مشابه
Metabolite and matrix interference in phenytoin immunoassays.
The major phenytoin metabolite, 5-(p-hydroxyphenyl)-5-phenylhydantoin glucuronide (HPPG), was primarily responsible for the positive bias noted when uremic specimens were assayed with the Abbott TDx Free Phenytoin fluorescence polarization immunoassay. The amount of bias depended on both HPPG and phenytoin concentration, increasing with increases in either concentration. The new Abbott TDx II a...
متن کاملThe antibody configurations of cardiac troponin I assays may determine their clinical performance.
BACKGROUND Previous studies have shown superior clinical performance of the cardiac troponin I (cTnI) assay from Beckman-Coulter Diagnostics. This assay had a unique combination of monoclonal antibodies with 2 monoclonal antibodies directed against epitopes near the NH(2) terminus of the heart-specific region of troponin I. The approach has been adopted by the new cTnI assay from Abbott Diagnos...
متن کاملMulti-site analytical evaluation of the Abbott ARCHITECT tacrolimus assay.
The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Tacrolimus immunoassay. Proficiency panels and specimens from a population of organ transplant recipients were analyzed in 6 clinical laboratories in Europe and the United States, and the results were compared with other methods. The ARCHITECT assay requires a whole blood specimen pretreatment step wi...
متن کاملReference population and marathon runner sera assessed by highly sensitive cardiac troponin T and commercial cardiac troponin T and I assays.
BACKGROUND Endurance exercise can increase cardiac troponin (cTn) concentrations as high as those seen in cases of minor myocardial infarction. The inability of most cTn assays to reliably quantify cTn at very low concentrations complicates a thorough data analysis, and the clinical implications of such increases remain unclear. The application of recently developed highly sensitive cTn immunoa...
متن کاملComparison of the Elecsys HBsAg II Assay and the Architect Assay for Quantification of hepatitis B surface antigen in patients with chronic hepatitis B.
Quantitative hepatitis B surface antigen (HBsAg) is a valuable tool in hepatitis B virus (HBV) disease diagnosis and management for evaluating the effectiveness of antiviral therapy. The aim of the current research was to compare the performances of the Elecsys HBsAg II and Abbott Architect HBsAg assays in chronic hepatitis B (CHB) patients. Between May 2014 and December 2014, 72 CHBs were test...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Laboratory medicine
دوره 45 2 شماره
صفحات -
تاریخ انتشار 2014