Can Tc 99m DTPA be Used in Adult Patients in Evaluation of Relative Renal Function Measurement as the Reference Tc 99m DMSA Method?
نویسندگان
چکیده
OBJECTIVE In the literature, there are many reports comparing relative renal function calculated with Tc 99m DTPA and Tc 99m DMSA in adults and children. However, there is no consensus about the results. As there is indeterminacy in the reliability of Tc 99m DTPA for the calculation of the relative renal functions, we retrospectively designed a study to compare the relative renal functions measured with Tc 99m DMSA and Tc 99m DTPA in adult patients with renal diseases Material and Methods: We retrospectively analyzed the data of 144 patients who applied to Nuclear Medicine Department of three hospitals between 2009 and 2010 and who had both dynamic and static renal imaging. Renal dynamic scintigraphies were compared to the relative function measured using Tc 99m DMSA static scintigraphy. Comparison of relative renal function measurements using dynamic and static renal scintigraphies was performed using Pearson correlation test. The comparison results were expressed with Bland-Altman analysis. RESULTS The study was conducted with 144 patients and 288 kidneys. Fifty six of patients were male. Mean age was 39.9±15.2 years. Thirty four patients had hydronephrosis, 28 pyelonephritis, 53 renal calculi, 3 chronic renal failure, 2 acute renal failure, 1 benign renal neoplasia, 15 renal atrophy, 8 ureteropelvic junction stenosis. Relative renal function was calculated in Tc 99m DMSA and 99m Tc-DTPA studies. The mean relative renal functions measured with Tc 99m DTPA was 52.54±23.09% and 47.25±23.09, with Tc 99m DMSA 52.85±21.80% and 47.07±21.77% for right and left kidneys, respectively. In bivariate correlation analysis (Pearson) a significant positive correlation was found between the relative renal functions calculated with Tc 99m DTPA and Tc 99m DMSA (r =0.937, p< 0.001). In Bland-Altman plots, the mean difference between two methods was 0.3 and the correlation limits were between 16.2 to -15.5. CONCLUSION As a result, we concluded that Tc 99m DTPA is also a good method for the relative renal function evaluation when compared to Tc 99m DMSA scan. Although Tc 99m DMSA is the most reliable method for the calculation of relative renal function, Tc 99m DTPA can be another choice for the calculation of relative renal function without a complementary DMSA scan particularly in patients who require renogram curve and GFR calculations. CONFLICT OF INTEREST None declared.
منابع مشابه
Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic
Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...
متن کاملAssessment of the individual renal function in chronic unilateral renal obstruction using functional CT as compared to 99mTc-DTPA renal scan
Introduction: The selection of optimal treatment of obstructive nephrouropathy requires information about the functional status of each kidney. Nuclear renal scanning objectively measure differential renal function, multiple studies have demonstrated the role of assessment of renal perfusion and GFR with triphasic CT. The aim of this study is to assess the role of CT based on renal parenchyma...
متن کاملThe comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size
Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...
متن کاملComparison of Tc-99m Ethylenedicysteine (Tc-99m EC) with Tc-99m DPTA in evaluation of renal disease [Persian]
Tc-99m-EC is a new renal radiopharmaceutical introduced as an alternative for Tc-99m MAG3. Twenty-three normal volunteers and patients in different .stages of renal disease were evaluated with Te-99m EC and Tc-99m DTPA. The mean initial uptake of EC was significantly higher as compared to DTPA. There was a high correlation between rectangular and hand-drawn ROls for kidney and background,...
متن کاملuse of 99m Tc-DMSA scintigraphy in assessment of renal complications of COVID-19
ABSTRACT COVID-19 mainly affects respiratory and immune systems, but other organs like renal, cardiovascular, lung and nervous systems could also be involved in both acute and chronic settings (1, 2). There is a lot of studies that demonstrate an increasing number of long COVID-19 who continue to experience persistent symptoms weeks or even months after the initial disease. Reports suggest...
متن کامل