Extent-based kinetic identification using spectroscopic measurements and multivariate calibration.
نویسندگان
چکیده
Extent-based kinetic identification is a kinetic modeling technique that uses concentration measurements to compute extents and identify reaction kinetics by the integral method of parameter estimation. This article considers the case where spectroscopic data are used together with a calibration model to predict concentrations. The calibration set is assumed to be constructed from reacting data that include pairs of concentration and spectral data. Alternatively, one can use the concentration- and spectral contributions of the reactions and mass transfers, which are obtained by pretreatment in reaction- and mass-transfer-variant form. The extent-based kinetic identification using concentrations predicted from spectroscopic data is illustrated through the simulation of both a homogeneous and a gas-liquid reaction system.
منابع مشابه
Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملIncremental Kinetic Modeling of Spectroscopic Data Using a Reduced Calibration Model
The identification of kinetic models is an important step for the monitoring, control and optimization of chemical processes. Kinetic models are often based on first principles that describe the evolution of concentrations by means of conservation and constitutive equations. Identification of reaction kinetics, namely, rate expressions and rate parameters, represents the main challenge in const...
متن کاملMultiway calibration for creatinine determination in human serum using the Jaffé reaction.
Second-order calibration and multivariate spectroscopic-kinetic measurements in the visible region are proposed to improve the Jaffé method for creatinine assay. Analyses performed on synthetic mixtures containing bilirubin, glucose, and albumin confirm that second-order calibration is useful for creatinine determination in human serum. Quantitative determinations of creatinine with the paralle...
متن کاملKinetic modeling of dissolution and crystallization of slurries with attenuated total reflectance UV-visible absorbance and near-infrared reflectance measurements.
Slurries are often used in chemical and pharmaceutical manufacturing processes but present challenging online measurement and monitoring problems. In this paper, a novel multivariate kinetic modeling application is described that provides calibration-free estimates of time-resolved profiles of the solid and dissolved fractions of a substance in a model slurry system. The kinetic model of this s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytica chimica acta
دوره 767 شماره
صفحات -
تاریخ انتشار 2013