A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, funded through the EPSRC Supergen V, UK Energy Infrastructure (AMPerES) grant in collaboration with UK electricity network operators has concentrated on the development of partial discharge data processing techniques that ultimately may allow continuous assessment of transmission asset health to be reliably determined.
منابع مشابه
Condition Monitoring Techniques of Power Transformers: A Review
Power transformers provide a vital link between the generation and distribution of produced energy. Such static equipment is subjected to abuse during operation in generation and distribution stations and leads to catastrophic failures. This paper reviewed the techniques in the field of condition monitoring of power transformers in recent years. Transformer monitoring and diagnosis are the effe...
متن کاملOn-site Portable Partial Discharge Detection Applied to Power Cables Using HFCT and UHF methods
Partial discharge (PD) events happen inside the power cables and cable terminations with the insulation degradation. The PD detection can effectively supply the information of cable status. According to the electrical and electromagnetic emission of PD activities, high-frequency transformer (HFCT) and ultrahigh-frequency (UHF) methods are employed to detect the PD signals. Besides, a portable P...
متن کاملElectrical and Thermal Analysis of Single Conductor Power Cable Considering the Lead Sheath Effect Based on Finite Element Method
This paper investigates the effect of metallic sheaths on losses and temperature of medium voltage power cables. Two grounding methods of sheaths, including both ends bonding and single point bonding that causes different situations on cable ampacity, are considered. Electrical losses of cables that are main sources of heat are calculated in both conductor and metallic sheath of the cables. She...
متن کاملContinuous On-line Condition Monitoring of HV Cable Systems
This paper discusses data acquisition, transmission and processing methodologies for continuous on-line monitoring of partial discharges in high voltage cable systems. A PD continuous on-line monitoring system for underground cable circuits using capacitive couplers, LiNbO3 electro-optic modulators, laser, optical switch and optical fibers has been developed. Future research will consider effec...
متن کاملDevelopment and Improvement of an Intelligent Cable Monitoring System for Underground Distribution Networks Using Distributed Temperature Sensing
With power systems switching to smart grids, real-time and on-line monitoring technologies for underground distribution power cables have become a priority. Most distribution components have been developed with self-diagnostic sensors to realize self-healing, one of the smart grid functions in a distribution network. Nonetheless, implementing a real-time and on-line monitoring system for underg...
متن کاملOn-line Partial Discharge Monitoring System and Data Processing Using WTST-NST Filter for High Voltage Power Cable
Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is placing a high frequency current transformer (HFCT) winding the grounded line. In order to measure the insulation degradation, a partial discharg...