Systematic review of the use of bone turnover markers for monitoring the response to osteoporosis treatment: the secondary prevention of fractures, and primary prevention of fractures in high-risk groups.
نویسندگان
چکیده
BACKGROUND There is currently no standard practice for the monitoring of patients receiving treatment for osteoporosis. Repeated dual-energy X-ray absorptiometry (DXA) is commonly used for monitoring treatment response, but it has its limitations. Bone turnover markers have advantages over DXA as they are non-invasive, relatively cheap and can detect changes in bone turnover rates earlier. However, they do have disadvantages, particularly high within- and between-patient variability. The ability of bone turnover markers to identify treatment non-responders and predict future fracture risk has yet to be established. OBJECTIVES We aimed to determine the clinical effectiveness, test accuracy, reliability, reproducibility and cost-effectiveness of bone turnover markers for monitoring the response to osteoporosis treatment. DATA SOURCES We searched 12 electronic databases (including MEDLINE, EMBASE, The Cochrane Library and trials registries) without language restrictions from inception to March 2012. We hand-searched three relevant journals for the 12 months prior to May 2012, and websites of five test manufacturers and the US Food and Drug Administration (FDA). Reference lists of included studies and relevant reviews were also searched. REVIEW METHODS A systematic review of test accuracy, clinical utility, reliability and reproducibility, and cost-effectiveness of two formation and two resorption bone turnover markers, in patients being treated for osteoporosis with any of bisphosphonate [alendronate (Fosamax, MSD), risedronate (Actonel, Warner Chilcott Company), zolendronate (Zometa, Novartis)], raloxifene (Evista, Eli Lilly and Company Ltd), strontium ranelate (Protelos, Servier Laboratories Ltd), denosumab (Prolia, Amgen Ltd) or teriparatide (Forsteo, Eli Lilly and Company Ltd), was undertaken according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Given the breadth of the review question, a range of study designs and outcome measures were eligible. The development of a decision model was planned to determine the cost-effectiveness of bone turnover markers for informing changes in patient management if clinical effectiveness could be established. RESULTS Forty-two studies (70 publications) met the inclusion criteria; none evaluated cost-effectiveness. Only five were randomised controlled trials (RCTs); these assessed only the impact of bone marker monitoring on aspects of adherence. No RCTs evaluated the effectiveness of bone turnover marker monitoring on treatment management. One trial suggested that feedback of a good response decreased non-persistence [hazard ratio (HR) 0.71, 95% confidence interval (CI) 0.53 to 0.95], and feedback of a poor response increased non-persistence (HR 2.22, 95% CI 1.27 to 3.89); it is not clear whether or not the trial recruited a population representative of that seen in clinical practice. Thirty-three studies reported results of some assessment of test accuracy, mostly correlations between changes in bone turnover and bone mineral density. Only four studies reported on intra- or interpatient reliability and reproducibility in treated patients. Overall, the results were inconsistent and inconclusive, owing to considerable clinical heterogeneity across the studies and the generally small sample sizes. As clinical effectiveness of bone turnover monitoring could not be established, a decision-analytic model was not developed. CONCLUSIONS There was insufficient evidence to inform the choice of which bone turnover marker to use in routine clinical practice to monitor osteoporosis treatment response. The research priority is to identify the most promising treatment-test combinations for evaluation in subsequent, methodologically sound, RCTs. In order to determine whether or not bone turnover marker monitoring improves treatment management decisions, and ultimately impacts on patient outcomes in terms of reduced incidence of fracture, RCTs are required. Given the large number of potential patient population-treatment-test combinations, the most promising combinations would initially need to be identified in order to ensure that any RCTs focus on evaluating those strategies. As a result, the research priority is to identify these promising combinations, by either conducting small variability studies or initiating a patient registry to collect standardised data. FUNDING The National Institute for Health Research Health Technology Assessment programme.
منابع مشابه
Recurrent hip fracture prevention with osteoporosis management
Abstract Background: Osteoporosis is a major public health threat, and hip fracture is a serious consequence of osteoporosis. Apatient with an osteoporosis-related hip fracture has an increased risk for a second hip fracture. The effect of osteoporosis management on the risk of recurrent hip fracture was evaluated in this study. Methods: 58 hip fracture patients older than 50yr and BMD < 2.5 w...
متن کاملEconomic Analysis of Bisphosphonate Use after Distal Radius Fracture for Prevention of Hip Fracture
Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...
متن کاملEfficacy of Corticosteroids in Prevention of Fat Embolism Syndrome in Patients with Long Bone Fracture
Fat embolism syndrome refers to a constellation of symptoms secondary to the presence of fat globules in the lung parenchyma and/or peripheral blood circulation. The syndrome is most often seen in association with long bone or pelvic fractures and can cause significant morbidity and mortality. The present randomized double blind placebo-controlled trial was conducted to evaluate the efficacy of...
متن کاملZoledronic Acid for the treatment and prevention of primary and secondary osteoporosis.
There is increasing interest in therapies that can be administered less frequently and/or avoid gastrointestinal irritation. The efficacy of once-yearly zoledronic acid (5 mg) in the treatment and prevention of osteoporosis has been evaluated in different patient populations. In the 3-year HORIZON-Pivotal Fracture Trial in postmenopausal women with osteoporosis, zoledronic acid reduced the risk...
متن کاملطراحی و اعتبار سنجی"فرم بررسی پوکی استخوان"
Background & Aims: Osteoporosis and the related fractures due to discomfort, disability, decreased quality of life and death are major health problems in the world. According to the importance of recording and reporting osteoporosis, the aim of this study was development and psychometric evaluation of an "Assessment Form of Osteoporosis". Materials & Methods: This study is a systematic review o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Health technology assessment
دوره 18 11 شماره
صفحات -
تاریخ انتشار 2014