Deep venous thrombosis: diagnostic value of non-contrast-enhanced MR venography using electrocardiography-triggered three-dimensional half-Fourier FSE.
نویسندگان
چکیده
We prospectively assessed the diagnostic accuracy of non-contrast-enhanced MR venography using both the flow-refocused fresh-blood imaging (FR-FBI) and the swap phase-encode arterial double-subtraction elimination (SPADE) techniques for detecting deep vein thrombosis (DVT), as compared using conventional X-ray venography as the reference standard. Forty-one legs of 32 consecutive patients (eight men, 24 women; mean age +/- standard deviation, 69.4 +/- 15.3 years) suspected of having deep vein thrombosis and thus examined using conventional X-ray venography underwent MR FR-FBI and SPADE. Twenty-five of the 32 patients had nonmagnetizing, metal implants they had received during hip or leg surgery. Two radiologists independently assessed the MR venograms as either diagnostic or nondiagnostic and with either the presence or absence of thrombi. The sensitivities of FR-FBI and SPADE for diagnosing thrombus were 100% (53 of 53) for both reviewers. Nondiagnostic segments were excluded from this analysis. The corresponding specificities were 100% (238 of 238 for reviewer A) and 99.6% (237 of 238 for reviewer B). The interobserver agreement regarding the MR images for the assessment of thrombosis was high (kappa = 0.92). Non-contrast-enhanced MR venography using SPADE and FR-FBI is highly accurate and reproducible for diagnosing DVT. This is especially advantageous for patients who have received nonmagnetizing, metal implants during orthopedic surgery.
منابع مشابه
Deep vein thrombosis using noncontrast-enhanced MR venography with electrocardiographically gated three-dimensional half-Fourier FSE: preliminary experience.
Three noncontrast-enhanced MR venography techniques are presented for assessing deep vein thrombosis (DVT) at 0.5 T in patients with metallic implants. Two cardiac-gated 3D half-Fourier FSE fresh blood imaging sequences with flow-refocusing pulses (FR-FBI) in the read-out (RO) direction and without FR pulses (non-FR-FBI) were developed for slower-flowing blood. For faster flowing blood, a swap ...
متن کاملDirect contrast-enhanced 3D MR venography evaluation of upper extremity deep venous system.
PURPOSE To investigate the diagnostic value of direct contrast-enhanced three dimensional magnetic resonance (3D MR) venography in mapping the deep venous system of the upper extremities and to plan potential interventional procedures. MATERIALS AND METHODS Nineteen cases with the diagnoses of end-stage renal disease with multiple hemodialysis catheter access were examined. Direct contrast-en...
متن کاملImaging of cerebral venous thrombosis: current techniques, spectrum of findings, and diagnostic pitfalls.
Cerebral venous thrombosis is a relatively uncommon but serious neurologic disorder that is potentially reversible with prompt diagnosis and appropriate medical care. Because the possible causal factors and clinical manifestations of this disorder are many and varied, imaging plays a primary role in the diagnosis. Magnetic resonance (MR) imaging, un-enhanced computed tomography (CT), unenhanced...
متن کاملEvaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.
BACKGROUND AND PURPOSE The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous flow on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, ...
متن کاملAmerican Thoracic Societv MEDICAL SECTION OF THE AMERICAN LUNG ASSOCIATiON The Diagnostic Approach to Acute Venous Thromboembolism
Introduction The Diagnostic Approach to Acute Deep Venous Thrombosis Background Symptoms and Signs Contrast Venography Impedance Plcthysmography Background Physiology and Techniyue Limitations of lmpedancc Plethysmography Early Clinical Trials: Establishing Accuracy in Symptomatic Acute Proximal DVT Management Studies: Early Success and Later Questions Impedance Plethysmography in Asymptomatic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 64 1 شماره
صفحات -
تاریخ انتشار 2010