BACKGROUND Large tumor motion often leads to larger treatment volumes, especially the lung tumor located in lower lobe and adhered to chest wall or diaphragm. The purpose of this work is to investigate the impacts of planning target volume (PTV) margin on Stereotactic Body Radiotherapy (SBRT) in non-small cell lung cancer (NSCLC). METHODS Subjects include 20 patients with the lung tumor located in lower lobe and adhered to chest wall or diaphragm who underwent SBRT. Four-dimensional computed tomography (4DCT) were acquired at simulation to evaluate the tumor intra-fractional centroid and boundary changes, and Cone-beam Computer Tomography (CBCT) were acquired during each treatment to evaluate the tumor inter-fractional set-up displacement. The margin to compensate for tumor variations uncertainties was calculated with various margin calculated recipes published in the exiting literatures. RESULTS The means (±standard deviation) of tumor centroid changes were 0.16 (±0.13) cm, 0.22 (±0.15) cm, and 1.37 (±0.81) cm in RL, AP, and SI directions, respectively. The means (±standard deviation) of tumor edge changes were 0.21 (±0.18) cm, 0.50 (±0.23) cm, and 0.19 (±0.44) cm in RL, AP, and SI directions, respectively. The means (±standard deviation) of tumor set-up displacement were 0.03 (±0.24) cm, 0.02 (±0.26) cm, and 0.02 (±0.43) cm in RL, AP, and SI directions, respectively. The PTV margin to compensate for lung cancer tumor variations uncertainties were 0.88, 0.98 and 2.68 cm in RL, AP and SI directions, which were maximal among all margin recipes. CONCLUSIONS 4DCT and CBCT imaging are appropriate to account for the tumor intra-fractional centroid, boundary variations and inter-fractional set-up displacement. The PTV margin to compensate for lung cancer tumor variations uncertainties can be obtained. Our results show that a conventional 1.0 cm margin in the SI plane dose not suffice to compensate the geometrical variety of the tumor located in lower lobe and adhered to chest wall and diaphragm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

Target repositional accuracy and PTV margin verification using three‐dimensional cone‐beam computed tomography (CBCT) in stereotactic body radiotherapy (SBRT) of lung cancers

The purpose of this study was to assess target repositional accuracy with respect to the bony structures using daily CBCT, and to validate the planning target volume (PTV) margin used in the lung SBRT. All patients underwent 4D CT scanning in preparation for lung SBRT. The internal target volume (ITV) was outlined from the reconstructed 4D data using the maximum-intensity projection (MIP) algor...

متن کامل

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy

BACKGROUND The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on t...

متن کامل

Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control

BACKGROUND To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung. METHODS 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 G...