Apparent diffusion coefficient normalization of normal liver

نویسندگان

  • Jie Zhu
  • Jie Zhang
  • Jia-Yin Gao
  • Jin-Ning Li
  • Da-Wei Yang
  • Min Chen
  • Cheng Zhou
  • Zheng-Han Yang
چکیده

Apparent diffusion coefficient (ADC) measurement in diffusion-weighted imaging (DWI) has been reported to be a helpful biomarker for detection and characterization of lesion. In view of the importance of ADC measurement reproducibility, the aim of this study was to probe the variability of the healthy hepatic ADC values measured at 3 MR scanners from different vendors and with different field strengths, and to investigate the reproducibility of normalized ADC (nADC) value with the spleen as the reference organ. Thirty enrolled healthy volunteers received DWI with GE 1.5T, Siemens 1.5T, and Philips 3.0T magnetic resonance (MR) systems on liver and spleen (session 1) and were imaged again after 10 to 14 days using only GE 1.5T MR and Philips 3.0T MR systems (session 2). Interscan agreement and reproducibility of ADC measurements of liver and the calculated nADC values (ADCliver/ADCspleen) were statistically evaluated between 2 sessions. In session 1, ADC and nADC values of liver were evaluated for the scanner-related variability by 2-way analysis of variance and intraclass correlation coefficients (ICCs). Coefficients of variation (CVs) of ADCs and nADCs of liver were calculated for both 1.5 and 3.0-T MR system. Interscan agreement and reproducibility of ADC measurements of liver and related nADCs between 2 sessions were found to be satisfactory with ICC values of 0.773 to 0.905. In session 1, the liver nADCs obtained from different scanners were consistent (P = 0.112) without any significant difference in multiple comparison (P = 0.117 to >0.99) by using 2-way analysis of variance with post-hoc analysis of Bonferroni method, although the liver ADCs varied significantly (P < 0.001). nADCs measured by 3 scanners were in good interscanner agreements with ICCs of 0.685 to 0.776. The mean CV of nADCs of both 1.5T MR scanners (9.6%) was similar to that of 3.0T MR scanner (8.9%). ADCs measured at 3 MR scanners with different field strengths and vendors could not be compared directly. Normalization of ADCs, however, may provide better reproducibility by overcoming these potential issues.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exploring the Possibility of Estimating Degree of Glioma Tumors by Measuring Apparent Diffusion Coefficient

Introduction: Most common glioma tumors are tumors of the central nervous system (CNS) which are the cause of about 40 to 50 percent of brain tumors. This type of cancer includes 2 to 3 percent of cancers in the world. Conventional MRI is powerless in the detection and differentiation of benign and malignant tumors. In this case, diffusion weighted imaging (DWI) can create cont...

متن کامل

Acute Normalization of apparent Diffusion Coefficient Values may not reflect tissue recovery in acute stroke patients

Figure 2. (a) ADC (unit 1×10 mm/s) changes in the presence and absence of reperfusion; (b)histogram of tp2 ADC in the reperfused ROI that did (infarct) and did not (noninfarct) go on infarction. The two vertical lines show ADC abnormal threshold (left) and normal mean (right). Figure 1. Representative ADC, MTT at tp1 and tp2 and FLAIR at tp3 from two patients. The range of the colorbar is from ...

متن کامل

Liver lobe-based magnetic resonance diffusion-weighted imaging using multiple b values in patients with hepatitis B-related liver cirrhosis: association with the liver disease severity according to the Child-Pugh class

OBJECTIVE To determine the associations of liver lobe-based magnetic resonance diffusion-weighted imaging findings using multiple b values with the presence and Child-Pugh class of cirrhosis in patients with hepatitis B. METHODS Seventy-four cirrhotic patients with hepatitis B and 25 healthy volunteers underwent diffusion-weighted imaging using b values of 0, 500, 800 and 1000 sec/mm2. The ap...

متن کامل

Predictors of apparent diffusion coefficient normalization in stroke patients.

BACKGROUND AND PURPOSE We sought to describe the frequency of normalization of apparent diffusion coefficient (ADC) values that are decreased in hyperacute stroke and to identify characteristics of tissue demonstrating normalization. METHODS Sixty-eight acute ischemic stroke patients underwent MRI examination (including diffusion/perfusion imaging and MR angiography) within 6 hours (mean, 2.8...

متن کامل

Intra-Individual, Inter-Vendor Comparison of Diffusion-Weighted MR Imaging of Upper Abdominal Organs at 3.0 Tesla with an Emphasis on the Value of Normalization with the Spleen.

OBJECTIVE To compare the apparent diffusion coefficient (ADC) values of upper abdominal organs with 2 different 3.0 tesla MR systems and to investigate the usefulness of normalization using the spleen. MATERIALS AND METHODS Forty-one patients were enrolled in this prospective study, of which, 35 patients (M:F, 27:8; mean age ± standard deviation, 62.3 ± 12.3 years) were finally analyzed. In a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017