Eccentricity dependent changes of density, spacing and packing arrangement of parafoveal cones.
نویسندگان
چکیده
PURPOSE To investigate the distribution of cone density and spacing as well as the preferred packing arrangement of the cone mosaic as a function of retinal eccentricity. METHODS An adaptive optics retinal camera (rtx1, www.imagine-eyes.com) was used to obtain images of the parafoveal cone mosaic in nineteen healthy volunteers. Cone density and spacing were estimated for each subject (both eyes) using a sampling window of 80 × 80 pixels, at 250-, 450-, 650- and 1100-μm eccentricities from the fovea along the nasal and temporal retina of both eyes. The inter-subject and intra-subject variation of cone density and spacing were calculated via Coefficient of Variation (CoV). Cone packing arrangement was assessed using Voronoi analysis; calculations were done over 1024 × 128 pixels image sections of the cone mosaic across the horizontal meridian from 200- to 1050-μm eccentricities. RESULTS The inter-subject variation of parafoveal cone density ranged between 10% and 15% (p < 0.001) and the intra-subject variation of cone density was lower than 8% in all subjects, except for two. The cone spacing values showed a moderate inter-subject (CoV<7%; p < 0.001) and a low intra-subject variation (CoV<4% in all subjects, except for two cases). In the parafoveal region, 40-50% of cones were hexagonally arranged; the percentage of non-hexagonal Voronoi tiles increased at greater eccentricities. CONCLUSION The use of multiple and complementary metric descriptors allows for a more detailed description of packing distribution and preferred arrangement of cone photoreceptors across the parafoveal retina.
منابع مشابه
Distribution of cone density, spacing and arrangement in adult healthy retinas with adaptive optics flood illumination
The aim of this article is to analyse cone density, spacing and arrangement using an adaptive optics flood illumination retina camera (rtx1™) on a healthy population. Cone density, cone spacing and packing arrangements were measured on the right retinas of 109 subjects at 2°, 3°, 4°, 5° and 6° of eccentricity along 4 meridians. The effects of eccentricity, meridian, axial length, spherical equi...
متن کاملInvestigation of Adaptive Optics Imaging Biomarkers for Detecting Pathological Changes of the Cone Mosaic in Patients with Type 1 Diabetes Mellitus
PURPOSE To investigate a set of adaptive optics (AO) imaging biomarkers for the assessment of changes of the cone mosaic spatial arrangement in patients with type 1 diabetes mellitus (DM1). METHODS 16 patients with ≥20/20 visual acuity and a diagnosis of DM1 in the past 8 years to 37 years and 20 age-matched healthy volunteers were recruited in this study. Cone density, cone spacing and Voron...
متن کاملPacking arrangement of the three cone classes in primate retina
We describe a detailed analysis of the spatial arrangement of L, M and S cones in the living eyes of two humans and one monkey. We analyze the cone mosaics near 1 degrees eccentricity using statistical methods that characterize the arrangement of each type of cone in the mosaic of photoreceptors. In all eyes, the M and L cones are arranged randomly. This gives rise to patches containing cones o...
متن کاملFoveal cone spacing and cone photopigment density difference: Objective measurements in the same subjects
Foveal cone spacing was measured in vivo using an objective technique: ocular speckle interferometry. Cone packing density was computed from cone spacing data. Foveal cone photopigment density difference was measured in the same subjects using retinal densitometry with a scanning laser ophthalmoscope. Both the cone packing density and cone photopigment density difference decreased sharply with ...
متن کاملStructure and arrangement of photoreceptors in the retina of big eye kilka, Clupeonella grimmi (Kessler 1877)
The big eye kilka, Clupeonella grimmi, is a marine fish living in depth of 20 to 200 meter of the Caspian Sea. Its eye and retina were processed for histological and SEM studies. Paraffin embedded retina was cut radially and tangentially in 5 ?m thickness and stained with hematoxylin and eosin method. The unstained sections were manipulated for SEM image observations. Tangential retinal sect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2013