A semiautomatic tool for prostate segmentation in radiotherapy treatment planning
نویسندگان
چکیده
BACKGROUND Delineation of the target volume is a time-consuming task in radiotherapy treatment planning, yet essential for a successful treatment of cancers such as prostate cancer. To facilitate the delineation procedure, the paper proposes an intuitive approach for 3D modeling of the prostate by slice-wise best fitting ellipses. METHODS The proposed estimate is initialized by the definition of a few control points in a new patient. The method is not restricted to particular image modalities but assumes a smooth shape with elliptic cross sections of the object. A training data set of 23 patients was used to calculate a prior shape model. The mean shape model was evaluated based on the manual contour of 10 test patients. The patient records of training and test data are based on axial T1-weighted 3D fast-field echo (FFE) sequences. The manual contours were considered as the reference model. Volume overlap (Vo), accuracy (Ac) (both ratio, range 0-1, optimal value 1) and Hausdorff distance (HD) (mm, optimal value 0) were calculated as evaluation parameters. RESULTS The median and median absolute deviation (MAD) between manual delineation and deformed mean best fitting ellipses (MBFE) was Vo (0.9 ± 0.02), Ac (0.81 ± 0.03) and HD (4.05 ± 1.3)mm and between manual delineation and best fitting ellipses (BFE) was Vo (0.96 ± 0.01), Ac (0.92 ± 0.01) and HD (1.6 ± 0.27)mm. Additional results show a moderate improvement of the MBFE results after Monte Carlo Markov Chain (MCMC) method. CONCLUSIONS The results emphasize the potential of the proposed method of modeling the prostate by best fitting ellipses. It shows the robustness and reproducibility of the model. A small sample test on 8 patients suggest possible time saving using the model.
منابع مشابه
Revision Report: A semiautomatic tool for prostate segmen- tation in radiotherapy treatment planning
متن کامل
Contribution of 68Ga-PSMA PET/CT to targeting volume delineation of prostate cancer treated with conformal radiation therapy: Which SUV threshold is appropriate?
Introduction: Prostate-specific membrane antigen (PSMA) has been demonstrated as a promising tool for specific imaging of prostate cancer (PCa) via positron emission tomography-computed tomography (PET/CT) scanning. Radiation treatment planning (RTP) based on 68Ga-PSMA PET/CT scanning can also lead to some decision modifications. The specific goal o...
متن کاملImage-guided prostate radiotherapy: analysis of inter- fractional setup errors
Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملاندازهگیری دوز جذبی مثانه و رکتوم در پرتودرمانی سرطان پروستات با روش دوزیمتری ترمولومینسانس
Background and Aim: Increased mortality rate�due to prostate cancer shows the growth of this disease.Prostate cancer is the second most widespread malignancy after lung cancer in men.It is important to use new methods in the radiation therapy of prostate cancer that are associated with lower exposure of the normal tissues. Nowadays, in most of the radiotherapy centers in our country, the Co-60 ...
متن کاملDosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer
Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...
متن کامل