Determination of sulfite in dried garlic by reversed-phase ion-pairing liquid chromatography with post-column detection.

نویسندگان

  • Gracia A Perfetti
  • Gregory W Diachenko
چکیده

A method is described for determining sulfite in dried garlic. Garlic is extracted with an HCl solution to inhibit the formation of allicin, which interferes with the determination of sulfite. After cleanup of the extract on a C18 solid-phase extraction column, sulfite is converted to hydroxymethylsulfonate (HMS) by adding formaldehyde and heating to 50 degrees C. HMS is determined by reversed-phase ion-pairing liquid chromatography with post-column detection. The post-column reaction system consists of the addition of KOH to convert HMS to sulfite ion, followed by the addition of 5,5'-dithiobis(2-nitrobenzoic acid) to produce 5-mercapto-2-nitrobenzoic acid which is detected spectrophotometrically at 450 nm. Background levels in unsulfited dried garlic equivalent to < 20 ppm SO2 were found. Recoveries of HMS from spiked garlic averaged 94.8% with a coefficient of variation of 3.8%. Sulfite was found in 13 of 21 samples of dried garlic produced in China, with sulfite ranging from 114 to 445 ppm. Sulfite was found in 60% of commercial dried garlic products purchased locally. The suitability of the Monier-Williams method for determining sulfite in garlic is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...

متن کامل

Reversed-phase Salt Assisted Liquid-liquid Extraction: A New Technique for Preconcentration and Determination of Crocin in Herbal Medicines by HPLC

A reversed-phase salt assisted liquid-liquid extraction (RP-SALLE) method was developed for the preconcentration and determination of trace crocin in herbal medicines by high-performance liquid chromatography (HPLC). In developed method, the roles of the aqueous and organic phases are inverted so that the analyte is extracted from the organic into the aqueous phase after salt addition and phase...

متن کامل

Simulataneous Analysis of Trimethoprim and Sulphamethoxazole Drug Combinations in Dosage Forms by High Performance Liquid Chromatography

A sensitive high performance liquid chromathography (HPLC) analytical procedure was developed for the quantitive determination of trimethoprim (TM* and sulphamethoxazole (SM) in commercial dosage forms. C18 analytical column (stainless steel, 25 cm * 4.6 mm i.d.) was packed with 5-*m particles of the reversed phase material and used for assays. Mobile phase containing 0.025 M sodium phosphate...

متن کامل

Determination of 18 ?-Glycyrrhetinic Acid in Glycyrrhiza glabra L. Extract by HPLC

A high performance liquid chromatography method was studied for determination of 18 ?-glycyrrhetinic acid in Glycyrrhiza glabra L. (licorice) extract. The operating condition were C-18 reversed phase column (VP-ODS, (250×4.6 mm, 5 mm)) at room temperature, acetonitril/phosphoric acid (3/1) as mobile phase, at flow rate of 0.6ml/min (0-8min), 0.4ml/min (8-20min) and UV detection at 230 nm. The...

متن کامل

Determination of 18 ?-Glycyrrhetinic Acid in Glycyrrhiza glabra L. Extract by HPLC

A high performance liquid chromatography method was studied for determination of 18 ?-glycyrrhetinic acid in Glycyrrhiza glabra L. (licorice) extract. The operating condition were C-18 reversed phase column (VP-ODS, (250×4.6 mm, 5 mm)) at room temperature, acetonitril/phosphoric acid (3/1) as mobile phase, at flow rate of 0.6ml/min (0-8min), 0.4ml/min (8-20min) and UV detection at 230 nm. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 86 3  شماره 

صفحات  -

تاریخ انتشار 2003