Automated static perimetry: the influence of myopic anisometropia on evaluation of visual field.

نویسندگان

  • Sanja Perić
  • Branimir Cerovski
  • Porin Perić
  • Ivan Skegro
  • Hrvoje Tiljak
چکیده

The aim of study was to establish which level of myopic refractive error influences visual field defects in automated static perimetry, if these defects are typical, and if optimal correction normalized the visual field. The study included 100 patients (200 eyes) divided into three groups according to the severity of the myopic refractive error: group A (till -3.25 Dsph), group B (-3.50 Dsph to -5.25 Dsph) and group C (-5.50 Dsph to -8.00 Dsph). The control group included 20 emmetropes (40 eyes). This study confirms that optimal corrected and uncorrected myopia up to -3.25 Dsph does not produce quantitative visual field defects, when tested by static automated perimetry. Even in optimally corrected myopics, with myopia higher than -5.50 Dsph, visual field defects on gray scale can be found. Defects are in the intermediary zone with more prominent defects in the upper quadrants. Visual field indices (MD, MS, LV RF) were completely normalized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.

The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...

متن کامل

Influence of Ocular Dominance on Anisometropic Myopia

During Binocular viewing, the preferential use of dominant eye because of its increased static ciliary muscle tone, might allow the dominant eye more myopic then non dominant eye in anisometropic myopia. However certain studies found that, there was no apparent association between ocular dominance and refraction. The present study was therefore conducted to analyze, the effect of ocular dominan...

متن کامل

Comparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases

Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...

متن کامل

Reclaiming the Periphery: Automated Kinetic Perimetry for Measuring Peripheral Visual Fields in Patients With Glaucoma.

Purpose Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Methods Thirty patients with glaucoma (median...

متن کامل

A comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.

OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 37 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2013