Electromagnetic inductance plethysmography is well suited to measure tidal breathing in infants
نویسندگان
چکیده
Reliable, accurate and noninvasive methods for measuring lung function in infants are desirable. Electromagnetic inductance plethysmography has been used to perform infant spirometry and VoluSense Pediatrics (VSP) (VoluSense, Bergen, Norway) represents an updated version of this technique. We aimed to examine its accuracy compared to a validated system measuring airflow via a facemask using an ultrasonic flowmeter. We tested 30 infants with postmenstrual ages between 36 to 43 weeks and weights from 2.3 to 4.8 kg, applying both methods simultaneously and applying VSP alone. Agreement between the methods was calculated using Bland-Altman analyses and we also estimated the effect of applying the mask. Mean differences for all breathing parameters were within ±5.5% and limits of agreement between the two methods were acceptable, except perhaps for peak tidal expiratory flow (PTEF). Application of the facemask significantly increased tidal volume, minute ventilation, PTEF, the ratio of inspiratory to expiratory time and the ratio of expiratory flow at 50% of expired volume to PTEF. VSP accurately measured tidal breathing parameters and seems well suited for tidal breathing measurements in infants under treatment with equipment that precludes the use of a facemask.
منابع مشابه
Lung function at term in extremely preterm-born infants: a regional prospective cohort study
OBJECTIVES To compare lung function of extremely preterm (EP)-born infants with and without bronchopulmonary dysplasia (BPD) with that of healthy term-born infants, and to determine which perinatal characteristics were associated with lung function at term and how predictive these measurements were for later respiratory health in EP-born infants. METHODS Perinatal variables were recorded pros...
متن کاملRespiratory inductance plethysmography in healthy infants: a comparison of three calibration methods.
Respiratory inductance plethysmography (RIP) measures respiration from body surface movements. Various techniques have been proposed for calibration in order that RIP may be used quantitatively. These include calculation of the proportionality constant of ribcage to abdominal volume change (K). The aims of this study were to 1) establish whether a fixed value of K could be used for calibration,...
متن کاملPressure sensor plethysmography: a method for assessment of respiratory motion in children.
Noncalibrated respiratory inductance plethysmography has been used to measure respiratory function by calculation of the phase angle and, more recently, by determination of the ratio of each time to reach peak tidal expiratory flow to total expiratory time (TPEF/TE). Since TPEF/TE is known to be decreased in airway obstruction when derived from flow signals obtained by a pneumotachograph, we wa...
متن کاملPulmonary Function Tests in Emergency Department Pediatric Patients with Acute Wheezing/Asthma Exacerbation
Background. Pulmonary function tests (PFT) have been developed to analyze tidal breathing in patients who are minimally cooperative due to age and respiratory status. This study used tidal breathing tests in the ED to measure asthma severity. Design/Method. A prospective pilot study in pediatric patients (3 to 18 yrs) with asthma/wheezing was conducted in an ED setting using respiratory inducta...
متن کاملPediatric Pulmonology 41:875–881 (2006) Synchronized Nasal Intermittent Positive Pressure Ventilation (SNIPPV) Decreases Work of Breathing (WOB) in Premature Infants With Respiratory Distress Syndrome (RDS) Compared to Nasal Continuous Positive Airway Pressure (NCPAP)
Synchronized nasal intermittent positive pressure ventilation (SNIPPV) is noninvasive respiratory support that delivers ventilator breaths via the nasal prongs.We hypothesized that SNIPPV is more effective than nasal continuous positive airway pressure (NCPAP) in premature neonates due to decreased work of breathing (WOB). Fifteen infants (BW: 1,367 325 g, GA: 29.5 2.4 weeks) were studied on (a...
متن کامل