Failure with continuity in rotator cuff repair "healing".
نویسندگان
چکیده
BACKGROUND Ten to seventy percent of rotator cuff repairs form a recurrent defect after surgery. The relationship between retraction of the repaired tendon and formation of a recurrent defect is not well defined. PURPOSE/ HYPOTHESES: To measure the prevalence, timing, and magnitude of tendon retraction after rotator cuff repair and correlate these outcomes with formation of a full-thickness recurrent tendon defect on magnetic resonance imaging, as well as clinical outcomes. We hypothesized that (1) tendon retraction is a common phenomenon, although not always associated with a recurrent defect; (2) formation of a recurrent tendon defect correlates with the timing of tendon retraction; and (3) clinical outcome correlates with the magnitude of tendon retraction at 52 weeks and the formation of a recurrent tendon defect. STUDY DESIGN Case series; Level of evidence, 4. METHODS Fourteen patients underwent arthroscopic rotator cuff repair. Tantalum markers placed within the repaired tendons were used to assess tendon retraction by computed tomography scan at 6, 12, 26, and 52 weeks after operation. Magnetic resonance imaging was performed to assess for recurrent tendon defects. Shoulder function was evaluated using the Penn score, visual analog scale (VAS) score for pain, and isometric scapular-plane abduction strength. RESULTS All rotator cuff repairs retracted away from their position of initial fixation during the first year after surgery (mean [standard deviation], 16.1 [5.3] mm; range, 5.7-23.2 mm), yet only 30% of patients formed a recurrent defect. Patients who formed a recurrent defect tended to have more tendon retraction during the first 6 weeks after surgery (9.7 [6.0] mm) than those who did not form a defect (4.1 [2.2] mm) (P = .08), but the total magnitude of tendon retraction was not significantly different between patient groups at 52 weeks. There was no significant correlation between the magnitude of tendon retraction and the Penn score (r = 0.01, P = .97) or normalized scapular abduction strength (r = -0.21, P = .58). However, patients who formed a recurrent defect tended to have lower Penn scores at 52 weeks (P = .1). CONCLUSION Early tendon retraction, but not the total magnitude, correlates with formation of a recurrent tendon defect and worse clinical outcomes. "Failure with continuity" (tendon retraction without a recurrent defect) appears to be a common phenomenon after rotator cuff repair. These data suggest that repairs should be protected in the early postoperative period and repair strategies should endeavor to mechanically and biologically augment the repair during this critical early period.
منابع مشابه
Characteristics of Rotator Cuff Repairs Revised to Shoulder Arthroplasty
Background: Successful repair of a torn rotator cuff may prevent progression to rotator cuff arthropathy. However,previous studies have shown a substantial rate of failure after rotator cuff repair and characteristics of surgicallyrepaired rotator cuffs that go on to shoulder arthroplasty have not been fully elucidated. The purpose of this study wasto determine the patient cha...
متن کاملPreliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix
Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...
متن کاملIncreasing age and tear size reduce rotator cuff repair healing rate at 1 year
Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients ...
متن کاملAll-arthroscopic patch augmentation of a massive rotator cuff tear: surgical technique.
Surgical management of massive rotator cuff tears remains challenging, with failure rates ranging from 20% to 90%. Multiple different arthroscopic and open techniques have been described, but there is no current gold standard. Failure after rotator cuff repair is typically multifactorial; however, failure of tendon-footprint healing is often implicated. Patch augmentation has been described as ...
متن کاملBiologically enhanced healing of the rotator cuff.
Failure of rotator cuff repair is a well-documented problem. Successful repair is impeded by muscle atrophy, fat infiltration, devascularization, and scar tissue formation throughout the fibrocartilagenous transition zone. This case study exemplifies a technique to biologically augment rotator cuff healing. Clinically, pain and function improved. Postoperative magnetic resonance imaging evaluat...
متن کاملThe role of repair tension on tendon to bone healing in an animal model of chronic rotator cuff tears.
Rotator cuff tendon tears are one of the most common shoulder injuries. Although surgical repair is typically beneficial, re-tearing of the tendons frequently occurs. It is generally accepted that healing is worse for chronic tears than acute tears, but the reasons for this are unknown. One potential cause may be the large tensions that are sometimes required to repair chronically torn tendons ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of sports medicine
دوره 41 1 شماره
صفحات -
تاریخ انتشار 2013