Tunnelling versus open harvest technique in obtaining venous conduits for coronary bypass surgery.

نویسندگان

  • H M Tran
  • H S Paterson
  • W Meldrum-Hanna
  • R B Chard
چکیده

BACKGROUND The tunnelling as opposed to the open harvest technique for harvesting long saphenous vein for coronary artery bypass procedures is a less frequently used technique as it requires more handling of the vein and this may induce trauma. This study aims to compare the degree of endothelial denudation and donor site morbidity between the two different harvest techniques. METHODS Saphenous vein segments in 78 patients (45 in tunnelling versus 33 in open harvest group) undergoing coronary artery bypass procedures were examined by light microscopy and graded according to the extent of endothelial denudation varying from grade 1 (most preserved) to grade 6 (>90% endothelial denudation). Clinical parameters relating to donor site morbidity including leg wound pain and infection were also assessed. RESULTS There was no statistical difference in the age, sex, macroscopic vein quality, length and time taken to harvest the veins between the two groups. The tunnelling technique always used thigh saphenous vein whereas nearly a third of veins harvested by the open harvest technique were lower leg veins (P=0.001). The tunnelling technique resulted in an endothelial score of 2.5 compared with 3.3 for the open harvest technique (P < 0.001). In addition, saphenous vein tunnelling resulted in significantly less leg wound pain (1.2 vs. 1.8, P=0.001), no leg wound infection (compared with 12.2% in open harvest group, P=0.02) and produced cosmetically more acceptable scars. Furthermore, length of hospital stay was significantly prolonged to 19.3 days in those with leg wound infection compared to 8.7 days in those without leg wound infection (P < 0.001). CONCLUSIONS These results show that saphenous vein tunnelling is an attractive alternative to the open harvest technique in obtaining venous conduits for coronary artery bypass procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic Conduit Harvest - A New Standard in Coronary Artery Bypass Surgery

Background/Introduction Coronary artery bypass grafting (CABG) remains an index procedure in cardiac surgery. Despite the increasing use of arterial conduits, the great saphenous vein remains the most widely used conduit due to its ease of harvest, availability and versatility. Traditional open harvesting technique (OVH) is associated with significant wound related morbidity and therefore an en...

متن کامل

Endoscopic vein harvest of the lesser saphenous vein in the supine position: a unique approach to an old problem.

OBJECTIVES To obtain a suitable conduit from the lesser (short) saphenous system for use in coronary artery bypass surgery. We wanted to perform this while the patient was in the supine position as to not disrupt the standard operation, and at the same time, utilizing the endoscopic vein harvest technique with its obvious abilities to decrease vein harvest morbidity. We also theorized that thro...

متن کامل

Clinical alternative bypass conduits and methods for surgical coronary revascularization.

Poor quality or inadequate length of venous and mammary conduits, or both, a severely calcified or atherosclerotic aorta, or diffuse coronary atherosclerosis are situations cardiovascular surgeons will be facing with increasing frequency. These conditions are more common to the increasing number of patients requiring reoperation for advancing disease and to the growing number of older patients ...

متن کامل

The Short Saphenous Vein: A Viable Alternative Conduit for Coronary Artery Bypass Grafts Harvested Using a Novel Technical Approach

A multitude of vascular conduits are available to the Cardiac Surgeon performing Coronary Artery Bypass Graft operations. The Internal Mammary Artery, Radial Artery (RA), and the Long Saphenous Vein (LSV) have proven to be excellent conduits, especially in the current era of statin usage. However, previous stripping or varicosities of the LSV and calcification of the RA, coupled with the need f...

متن کامل

Conduits for Coronary Bypass: Arteries Other Than the Internal Thoracic Artery's

This is the third in a series on coronary artery bypass which reviews three alternative arterial conduits. The radial artery has become the most widely used of the three and accumulating experience demonstrates better patency at 10 years versus saphenous vein. Drawbacks are a long incision on the forearm, the propensity for spasm and persistent sensory disturbance in about 10%. The first is ans...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 1998