On the use of certified reference materials for assuring the quality of results for the determination of mercury in environmental samples

نویسندگان

  • Ewa Bulska
  • Agnieszka Krata
  • Mateusz Kałabun
  • Marcin Wojciechowski
چکیده

This work focused on the development and validation of methodologies for the accurate determination of mercury in environmental samples and its further application for the preparation and certification of new reference materials (RMs). Two certified RMs ERM-CC580 (inorganic matrix) and ERM-CE464 (organic matrix) were used for the evaluation of digestion conditions assuring the quantitative recovery of mercury. These conditions were then used for the digestion of new candidates for the environmental RMs: bottom sediment (M_2 BotSed), herring tissue (M_3 HerTis), cormorant tissue (M_4 CormTis), and codfish muscle (M_5 CodTis). Cold vapor atomic absorption spectrometry (CV AAS) and inductively coupled plasma mass spectrometry (ICP MS) were used for the measurement of mercury concentration in all RMs. In order to validate and assure the accuracy of results, isotope dilution mass spectrometry (IDMS) was applied as a primary method of measurement, assuring the traceability of obtained values to the SI units: the mole, the kilogram, and the second. Results obtained by IDMS using n(200Hg)/n(202Hg) ratio, with estimated combined uncertainty, were as follows: (916 ± 41)/[4.5 %] ng g-1 (M_2 BotSed), (236 ± 14)/[5.9 %] ng g-1 (M_3 HerTis), (2252 ± 54)/[2.4 %] ng g-1 (M_4 CormTis), and (303 ± 15)/[4.9 %] ng g-1 (M_CodTis), respectively. Different types of detection techniques and quantification (external calibration, standard addition, isotope dilution) were applied in order to improve the quality of the analytical results. The good agreement (within less than 2.5 %) between obtained results and those derived from the Inter-laboratory Comparison, executed by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland) on the same sample matrices, further validated the analytical procedures developed in this study, as well as the concentration of mercury in all four new RMs. Although the developed protocol enabling the metrological certification of the reference value was exemplified by the determination of mercury in environmental samples, it could be considered as valid for any certification procedure required whenever new certified RMs are introduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining Total Mercury in Samples from the Persian Gulf and theCaspian Sea: Comparison of Dry Ash and Wet Extraction Mothods

Monitoring of mercury in environmental samples, with its proven toxicity on the food chain, requires sensitive and accurate analytical techniques. In this study, two methods for identification and quantification of total mercury in biological and sediment samples are compared: i) dry ash preparation and subsequent established procedures for Combustion Atomic Absorption Spectrometry, (AMA 254) ...

متن کامل

Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)

In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...

متن کامل

Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid

Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...

متن کامل

Certified reference materials for quality control of mercury and selenium determination in food.

Several certified reference materials were used for quality control of mercury and selenium determination in food through different analytical procedures and techniques. The materials were selected with respect to different composition of matrix and levels of certified values. The results agreed well with the certified values for all analysed materials.

متن کامل

Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction

A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...

متن کامل