C3an00544e 5965..5972

نویسندگان

  • Cecilie Rosting
  • Stig Pedersen-Bjergaard
  • Steen Honoré Hansen
  • Christian Janfelt
چکیده

Biological fluids such as urine, saliva and whole blood were analyzed for contents of drugs by a new combination of desorption electrospray ionization mass spectrometry (DESI-MS) and thin liquid membrane extraction (TLME). Analytes from the sample were extracted into a thin liquid membrane of hexadecane deposited on a porous Teflon membrane, from which they were subsequently analyzed directly by DESI. The total analysis time was 15 minutes for analysis of several samples with a potential analysis time of less than a minute per sample. Thanks to the pre-concentration and sample clean-up built into the method, methadone was detected in urine in full-scan mode with an LOD of 4 ng mL , while amitriptyline, nortriptyline and pethidine showed LODs of 17 ng mL . Quantification was possible for several basic drugs using one common internal standard, providing relative accuracies in the range of 10–30%. A reliability test was performed on 20 samples with methadone, amitriptyline, nortriptyline and pethidine in urine, showing that none of the samples having concentrations above the LOD were missed and no false positives were found. Diphenhydramine and one of its metabolites were detected in authentic samples of urine and saliva, and methadone was detected from a whole-blood sample spiked to a concentration of 100 ng mL . The method has several advantages, such as extremely low price in consumables, the possibility of fast analysis of very crude biofluids such as whole blood and the potential for a very high sample throughput.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evolution of Fairness and Punishment Markets

This copy is for your personal, non-commercial use only. . clicking here colleagues, clients, or customers by , you can order high-quality copies for your If you wish to distribute this article to others . here following the guidelines can be obtained by Permission to republish or repurpose articles or portions of articles (this information is current as of March 18, 2010 ): The following resou...

متن کامل

MPEG-4: Why, what, how and when?

The MPEG-4 Version 1 standard has been recently finalized. Since MPEG-4 adopted an objectbased audiovisual representation model with hyperlinking and interaction capabilities and supports both natural and synthetic content, it is expected that this standard will become the information coding playground for future multimedia applications. This paper intends to give an overview on the MPEG-4 moti...

متن کامل

A fast and efficient compression method for binary images

The use of arithmetic coding for binary image compression achieves a high compression ratio while the running time remains rather slow. A composite modelling method presented in this paper reduces the size of the data to be coded by arithmetic coding. The method is to code the uniform areas with less computation and apply arithmetic coding to the areas with more variation.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013