Performance of Hybrid Reactive Power Compensators in a Multi-terminal Hvdc Transmission System Feeding Weak Ac Networks during Transient Fault Conditions

نویسندگان

  • S. Singaravelu
  • S. Seenivasan
چکیده

In this paper performance analysis of various hybrid reactive power compensators (RPC’s) at the inverter AC sides of a line commutated converter (LCC) based multi-terminal HVDC (MTDC) transmission system, feeding weak AC networks, is carried out to thoroughly gather the mechanisms of interactions between an HVDC system and weak AC systems. The hybrid compensator is realized by equally mixing the fixed capacitor (FC) with any one of the following compensators: synchronous compensator (SC); static var compensator (SVC); static synchronous compensator (STATCOM). The HVDC transmission system model is simulated using Matlab with firefly algorithm based optimal proportional integral (PI) controller for rectifiers and inverters control. The performances of hybrid RPC’s (FC+SC, FC+SVC and FC+STATCOM) are investigated during various transient fault conditions and the results are compared with the performance of the SC, SVC and STATCOM to focus the supremacy of the hybrid compensators. The simulation results authorize that the equal combination of FC and STATCOM has a steady and fastest response. The outcomes also demonstrate the superiority of the firefly algorithm based optimal PI controller over the conventional PI controller. The harmonic existing in the inverter AC side is also observed under steady state operation to ascertain the quality of power supply.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Multi-terminal Hvdc Transmission System Feeding Very Weak Ac Networks

This paper presents a line commutated converter (LCC) based multi-terminal HVDC transmission (MTDC) system feeding very weak AC networks with hybrid reactive power compensators (RPC’s) at the inverter AC side. The hybrid compensator is accomplished by the equal mixing of any two of the following compensators: synchronous compensator (SC); static var compensator (SVC); static synchronous compens...

متن کامل

Performance Investigation of a Monopolar HVDC Transmission System Feeding a Weak AC Network

This paper investigates the performance of line commutated converter (LCC) based monopolar HVDC transmission system feeding a weak AC network with hybrid reactive power compensators (RPC’s) at the inverter AC side. The hybrid compensator is an equal mix of any two of the following compensators: synchronous compensator (SC); static var compensator (SVC); static synchronous compensator (STATCOM)....

متن کامل

Control and Transient Analysis of Voltage Source Converter Based Multi Terminal Dc System

As one of the key technologies of large scale access of distributed energy resources, the HVDC transmission system has great potential for further development. Therefore, in the past decades, the problem associated with HVDC converters connected to weak AC networks has become an important research field. The one of particular interest, and highest in consequences, is the AC voltage stability at...

متن کامل

Fast Transient Hybrid Neuro Fuzzy Controller for STATCOM During Unbalanced Voltage Sags

A static synchronous compensator (STATCOM) is generally used to regulate voltage and improve transient stability in transmission and distribution networks. This is achieved by controlling reactive power exchange between STATCOM and the grid. Unbalanced sags are the most common type of voltage sags in distribution networks. A static synchronous compensator (STATCOM) is generally used to maintain...

متن کامل

Multi-Terminal HVDC Networks - What is the Preferred Topology?

This paper investigates the influence of the DC network topology with respect to two important aspects: the steady-state losses and the transient fault currents. For this, the optimal power flow in a combined AC-DC Multi-Terminal HVDC cable system based on Voltage Source Converters and the development of prospective fault currents during a pole-toground fault is simulated. The results prove tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015