Impact of Catheter Sheath Insertion into the Radial Artery on Vascular Endothelial Function Assessed by Reactive Hyperemia Peripheral Arterial Tonometry.
نویسندگان
چکیده
The transradial approach has been used for coronary procedures, but this procedure carries a risk of injury to the endothelium of the radial artery. In this study, the vascular dysfunction caused by transradial catheterization was examined using reactive hyperemia peripheral arterial tonometry (RH-PAT), a recently developed technique for assessing endothelial function in digits, and the differences in injuries were compared according to the size of sheath.Forty-three patients undergoing transradial catheterization with 6-Fr sheaths (n = 17) or 4-Fr/5-Fr (non-6-Fr; n = 26) sheaths underwent RH-PAT using an Endo-PAT2000 before, the day after, and 6 months after catheterization. RH-PAT was assessed in the arm of sheath placement and in the other arm as a control.RH-PAT values decreased from 2.42 ± 0.67 before catheterization to 2.08 ± 0.41 the day after catheterization in the 6-Fr group (P = 0.031); this was more evident in patients with a longer procedure time (> 91 minutes). In contrast, the change in the non-6-Fr group was not significant. RH-PAT of the non-catheterized arm was unchanged in both groups. At 6 months after catheterization, RH-PAT values in the 6-Fr group had not completely returned to baseline.In conclusion, the insertion of a 6-Fr catheter sheath into the radial artery, especially with a longer procedure time, impaired vascular endothelial function assessed by RH-PAT the day after the procedure and was sustained for 6 months. Thus, the use of smaller size sheaths (< 6-Fr) with a shorter procedure should be considered when performing transradial catheterization.
منابع مشابه
Assessment of endothelial function. History, methodological aspects, and clinical perspectives.
In 1986, endothelial function was measured for the first time in patients with atherosclerotic coronary arteries. Since then, several methods for assessment of endothelial function, such as endothelium-dependent vasodilation induced by intra-arterial infusion of vasoactive agents using coronary angiography, Doppler flow guide wire, mercury-filled Silastic strain-gauge plethysmography, flow-medi...
متن کاملMicrovascular endothelial function in Japanese early adolescents
Endothelial dysfunction is the early predictive factor for the development of atherosclerosis and future cardiovascular diseases in adulthood. The prevalence of endothelial dysfunction in children and early adolescents is increasing worldwide. Peripheral arterial tonometry is a noninvasive technique for assessing peripheral microvascular function and is used as a validated marker of endothelial...
متن کاملAssessment of peripheral vascular endothelial function in the ambulatory setting.
Until now, peripheral vascular endothelial function testing has been performed in research laboratories under highly controlled conditions, thus limiting its clinical applicability. In this study, we evaluated endothelial function in two peripheral vascular beds before and during reactive hyperemia in an outpatient clinic setting. The brachial artery was imaged with a portable ultrasound device...
متن کاملEndothelial dysfunction in patients with Buerger disease
We evaluated the endothelial function of patients with Buerger disease using peripheral arterial tonometry test, and examined the factors that are significantly correlated with the endothelial dysfunction in these patients. We performed the peripheral arterial tonometry test in 22 patients with Buerger disease. We recorded the patients' characteristics, including ankle brachial pressure index a...
متن کاملEndothelial function testing and cardiovascular disease: focus on peripheral arterial tonometry
During recent decades, a number of methods have been developed to assess endothelial function, contributing to a better understanding of the pathophysiology of cardiovascular disease. Recently, the advent of noninvasive, reproducible techniques for assessment of endothelial function has opened novel possibilities of application in the clinical setting. Peripheral arterial tonometry is a relativ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International heart journal
دوره 56 5 شماره
صفحات -
تاریخ انتشار 2015