PURPOSE To determine the changes in stability as a reflection of early healing around single-stage, roughened-surface implants in humans utilizing resonance frequency analysis (RFA). RFA makes use of a transducer, attached to an implant, which is excited over a range of sound frequencies with subsequent response analysis. MATERIALS AND METHODS Twenty patients had 1 to 4 implants placed in the posterior maxilla or mandible. Bone type was classified into 1 of 4 groups according to the Lekholm and Zarb index (1985). RFA was used for direct measurement of implant stability on the day of implant placement and consecutively once per week for 6 weeks and at weeks 8 and 10. RESULTS Twenty-seven ITI SLA implants placed in the premolar and molar regions of the maxilla and mandible were evaluated. Early failure occurred with 1 implant related to parafunction. The remaining 26 implants were distributed as follows: 29.6% in Type 1 bone, 37% in Type 2 or 3 bone, and 33.3% in Type 4 bone. The lowest mean stability measurement was at 3 weeks for all bone types. The percentage decrease in stability from baseline to 3 weeks was highest for Type 4 bone (8.6%), as was the percentage increase in stability from 3 to 10 weeks (26.9%). A Bonferroni adjusted Student t test comparison of bone groups at each time point revealed highly significant differences between implant stability in Types 1 and 4 bone at 3 weeks (P = .004) and a moderately significant difference between Types 2, 3, and 4 bone (P = .08) at 3 weeks. Implant stability did not change significantly during the 10-week period in Type 1 bone (P > .10). With the same test, by 5 weeks, no bone groups showed any difference in implant RFA measurements (P = 1.0). DISCUSSION This study demonstrated the lowest values for implant stability at 3 weeks after placement for all bone types. This effect was statistically significant and most pronounced in Type 4 bone. CONCLUSION There was no significant difference in the pattern of stability changes among different bone types after 5 weeks of healing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface analysis of machined versus sandblasted and acid-etched titanium implants.

Initially, implant surface analyses were performed on 10 machined implants and on 10 sandblasted and acid-etched implants. Subsequently, sandblasted and acid-etched implant cytotoxicity (using L929 mouse fibroblasts), morphologic differences between cells (osteoblast-like cells MG63) adhering to the machined implant surfaces, and cell anchorage to sandblasted and acid-etched implant surfaces we...

متن کامل

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

PURPOSE The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess i...

متن کامل

Sandblasted and acid-etched dental implants: a histologic study in rats.

PURPOSE Current literature has revealed that surface etching of endosseous implants can improve bone-implant contact. The aim of this study was to evaluate the differences in bone-implant contact (BIC) between sandblasted/acid-etched and machined-surface implants. MATERIALS AND METHODS Thirty-two Sprague-Dawley rats were used in this study. Two implant surfaces, Ecotek (sandblasted/ acid-etch...

متن کامل

Adult Stem Cells Properties in Terms of Commitment, Aging and Biological Safety of Grit-Blasted and Acid-Etched Ti Dental Implants Surfaces

Titanium (Ti) is one of the most widely used biomaterials for manufacturing dental implants. The implant surface properties strongly influence osseointegration. The aim of the present study was to in vitro investigate the characteristics of Ti dental implants in terms of mutagenicity, hemocompatibility, biocompatibility, osteoinductivity and biological safety. The Ames test was used to test the...

متن کامل

Biomechanical comparison of different surface modifications for dental implants.

PURPOSE A satisfactory clinical outcome in dental implant treatment relies on primary stability for immediate load bearing. While the geometric design of an implant contributes to mechanical stability, the nature of the implant surface itself is also critically important. Biomechanical and microcomputerized tomographic evaluation of implant osseointegration was performed to compare alternative ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2003