Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement
نویسندگان
چکیده
An assessment of the sensitivities of the critical parameters in the ASTM D6423 documentary standard method for the measurement of pHe in (bio)ethanol has been undertaken. Repeatability of measurements made using the same glass electrode and reproducibility between different glass electrodes have been identified as the main contributors to the uncertainty of the values produced. Strategies to reduce the uncertainty of the measurement have been identified and tested. Both increasing the time after which the pHe measurement is made following immersion in the sample, and rinsing the glass electrode with ethanol prior to immersion in the sample, have been shown to be effective in reducing the uncertainty of the numerical value produced. However, it is acknowledged that the values produced using these modified approaches may not be directly compared with those obtained using the documentary ASTM method since pHe is defined operationally by the process used to measure it.
منابع مشابه
New Enzymatic Colorimetric Method for the Quantitative Determination of Phenylalanine in Dry-Blood Spots
Phenylketonuria (PKU) is an autosomal recessive disorder, which is characterized by severe mental retardation, microcephaly and seizures. The symptoms of this disease can be prevented if detected soon after birth. Therefore, blood Phenylalanine (Phe) measurement is essential for the early diagnosis, treatment and dietary monitoring of PKU patients. The goal of this research was to introduce a r...
متن کاملElectrochemical Behavior and Determination of Phenylephrine at the Multi-Walled Carbon Nanotubes/ionic Liquid Nanocomposite Modified Electrode in the Presence of Acetaminophen
A simple and high sensitive electrochemical method was developed for determination of phenylephrine (PHE) in the presence of acetaminophen (AC) at the carbon-ceramic electrode modified by multi-walled carbon nanotubes/ionic liquid nanocomposite (MWCNTs/IL/CCE). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) and chronoamperometry methods were used for electrochemical studie...
متن کاملSimple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma
Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...
متن کاملDevelopment of a GC-MS Method for Determination of various Polycyclic Aromatic Hydrocarbons in Iranian Traditional and Semi-industrial Taftoon Bread
This research reports a validated multi-residue method based on gas chromatography coupled mass spectrometry technique for analysis of 24 Polycyclic Aromatic Hydrocarbons (PAHs) in traditional and semi-industrial Taftoon bread using QuEChERS sample preparation. Matrix effect studies were performed by comparing the slopes of solvent based standard calibration curves and spiked calibration curves...
متن کاملDevelopment of a GC-MS Method for Determination of various Polycyclic Aromatic Hydrocarbons in Iranian Traditional and Semi-industrial Taftoon Bread
This research reports a validated multi-residue method based on gas chromatography coupled mass spectrometry technique for analysis of 24 Polycyclic Aromatic Hydrocarbons (PAHs) in traditional and semi-industrial Taftoon bread using QuEChERS sample preparation. Matrix effect studies were performed by comparing the slopes of solvent based standard calibration curves and spiked calibration curves...
متن کامل