Revisiting stopping rules for iterative methods used in emission tomography
نویسندگان
چکیده
The expectation maximization algorithm is commonly used to reconstruct images obtained from positron emission tomography sinograms. For images with acceptable signal to noise ratios, iterations are terminated prior to convergence. A new quantitative and reproducible stopping rule is designed and validated on simulations using a Monte-Carlo generated transition matrix with a Poisson noise distribution on the sinogram data. Iterations are terminated at the solution which yields the most probable estimate of the emission densities while matching the sinogram data. It is more computationally efficient and more accurate than the standard stopping rule based on the Pearson's χ(2) test.
منابع مشابه
A Nonnegatively Constrained Iterative Method with Statistically Based Stopping Rules for Ct, Pet, and Spect Imaging
In this paper, we extend a nonnegatively constrained iterative method and three stopping rules for its iterations to the medical imaging inverse problems of computed tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT); the iterative method and stopping rules were introduced for use in astronomical imaging. The paper begins with a brief int...
متن کاملApplications of a Nonnegatively Constrained Iterative Method with Statistically Based Stopping
In this paper, we extend a nonnegatively constrained iterative method and three stopping rules for its iterations to the medical imaging inverse problems of computed tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT); the iterative method and stopping rules were introduced for use in astronomical imaging. The paper begins with a brief int...
متن کاملGradient-based stopping rules for maximum-likelihood quantum-state tomography
When performing maximum-likelihood quantum-state tomography, one must find the quantum state that maximizes the likelihood of the state given observed measurements on identically prepared systems. The optimization is usually performed with iterative algorithms. This paper provides a gradient-based upper bound on the ratio of the true maximum likelihood and the likelihood of the state of the cur...
متن کاملAn Nonnegatively Constrained Iterative Method for Positron Emission Tomography
In positron emission tomography (PET), data is collected via the detection of photons emitted by a radioactive tracer within the subject. The noise in PET data is Poisson, and hence, it is typical to reconstruct the tracer density distribution via the computation of an approximate minimizer of the negative-log Poisson likelihood function. In this paper, we present an iterative method for the so...
متن کاملStudying the properties of the updating coefficients in the OSEM algorithm for iterative image reconstruction in PET
We have studied the properties of the pixel updating coefficients in the 2D ordered subsets expectation maximization (OSEM) algorithm for iterative image reconstruction in positron emission tomography, in order to address the problem of image quality degradation-a known property of the technique after a number of iterations. The behavior of the updating coefficients has been extensively analyze...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
دوره 35 5 شماره
صفحات -
تاریخ انتشار 2011