Initial clinical experience with ambulatory use of an implantable atrial defibrillator for conversion of atrial fibrillation. Metrix Investigators.

نویسندگان

  • E G Daoud
  • C Timmermans
  • C Fellows
  • R Hoyt
  • R Lemery
  • K Dawson
  • G M Ayers
چکیده

BACKGROUND A recent study has shown that the implantable atrial defibrillator can restore sinus rhythm in patients with recurrent atrial fibrillation when therapy was delivered under physician observation. The objective of this study was to evaluate the safety and efficacy of ambulatory use of the implantable atrial defibrillator. METHODS AND RESULTS An atrial defibrillator was implanted in 105 patients (75 men; mean age, 59+/-12 years) with recurrent, symptomatic, drug-refractory atrial fibrillation. After successful 3-month testing, patients could transition to ambulatory delivery of shock therapy. Patients completed questionnaires regarding shock therapy discomfort and therapy satisfaction using a 10-point visual-analog scale (1 represented "not at all," 10 represented "extremely") after each treated episode of atrial fibrillation. During a mean follow-up of 11.7 months, 48 of 105 patients satisfied criteria for transition and received therapy for 275 episodes of atrial fibrillation. Overall shock therapy efficacy was 90% with 1.6+/-1.2 shocks delivered per episode (median, 1). Patients rated shock discomfort as 5.2+/-2.4 for successful therapy and 4.2+/-2.2 for unsuccessful therapy (P:>0.05). The satisfaction score was higher for successful versus unsuccessful therapy (3.4+/-3. 3 versus 8.7+/-1.3, P:<0.05). There was no ventricular proarrhythmia observed throughout the course of this study. CONCLUSIONS Ambulatory use of an implantable atrial defibrillator can safely and successfully convert most episodes of atrial fibrillation, often requiring only a single shock. Successful therapy is associated with high satisfaction and only moderate discomfort.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initial Clinical Experience With Ambulatory Use of an Implantable Atrial Defibrillator for Conversion of Atrial Fibrillation

Background—A recent study has shown that the implantable atrial defibrillator can restore sinus rhythm in patients with recurrent atrial fibrillation when therapy was delivered under physician observation. The objective of this study was to evaluate the safety and efficacy of ambulatory use of the implantable atrial defibrillator. Methods and Results—An atrial defibrillator was implanted in 105...

متن کامل

Atrial fibrillation detection and R-wave synchronization by Metrix implantable atrial defibrillator: implications for long-term efficacy and safety. The Metrix Investigators.

BACKGROUND The long-term efficacy of atrial fibrillation (AF) detection and R-wave synchronization are critical safety requirements for the development of an implantable atrial defibrillator (IAD) for treatment of AF. METHODS AND RESULTS The long-term efficacy of the Metrix IAD for AF detection and R-wave synchronization was tested in 51 patients. The mean duration of follow-up was 259+/-138 ...

متن کامل

Use of sedation during cardioversion with the implantable atrial defibrillator.

BACKGROUND The low shock energy used during internal atrial defibrillation may decrease the need for sedation during defibrillation with an implantable atrial defibrillator. METHODS AND RESULTS The atrial defibrillator (Metrix Atrioverter) was implanted in 12 patients. During the in-hospital treatment of atrial fibrillation (AF) episodes, intravenous sedation was given only on patient request...

متن کامل

Effect of the implantable atrial defibrillator on the natural history of atrial fibrillation.

INTRODUCTION The purpose of our study was to evaluate the effect of repeated cardioversion with an implantable atrial defibrillator on the clinical outcome of patients with atrial fibrillation. METHODS AND RESULTS The effects of the implantable atrial defibrillator on the total duration of atrial fibrillation, number of atrial fibrillation recurrences, and left atrial size were evaluated pros...

متن کامل

Dual‐chamber implantable cardioverter–defibrillator. Is it useful in patient with permanent atrial fibrillation?

In patients with permanent atrial fibrillation (AF) and implantable cardioverter-defibrillator (ICD) implant indication, a single-chamber device is the choice because AF does not provide interesting information for the treatment. It is very unusual to find patients with permanent AF that coexist with atrial tachycardia with various degree of Atrioventricular block.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 102 12  شماره 

صفحات  -

تاریخ انتشار 2000