Dosimetric impacts of endorectal balloon in CyberKnife stereotactic body radiation therapy (SBRT) for early‐stage prostate cancer
نویسندگان
چکیده
PURPOSE In SBRT for prostate cancer, higher fractional dose to the rectum is a major toxicity concern due to using smaller PTV margin and hypofractionation. We investigate the dosimetric impact on rectum using endorectal balloon (ERB) in prostate SBRT. MATERIALS AND METHODS Twenty prostate cancer patients were included in a retrospective study, ten with ERB and 10 without ERB. Optimized SBRT plans were generated on CyberKnife MultiPlan for 5 × 7.25 Gy to PTV under RTOG-0938 protocol for early-stage prostate cancer. For the rectum and the anterior half rectum, mean dose and percentage of volumes receiving 50%, 80%, 90%, and 100% prescription dose were compared. RESULTS Using ERB, mean dose to the rectum was 62 cGy (P = 0.001) lower per fraction, and 50 cGy (P = 0.024) lower per fraction for the anterior half rectum. The average V50% , V80% , V90% , and V100% were lower by 9.9% (P = 0.001), 5.3% (P = 0.0002), 3.4% (P = 0.0002), and 1.2% (P = 0.005) for the rectum, and lower by 10.4% (P = 0.009), 8.3% (P = 0.0004), 5.4% (P = 0.0003), and 2.1% (P = 0.003) for the anterior half rectum. CONCLUSIONS Significant reductions of dose to the rectum using ERB were observed. This may lead to improvement of the rectal toxicity profiles in prostate SBRT.
منابع مشابه
Prostate-specific antigen kinetics after hypofractionated stereotactic body radiotherapy for localized prostate cancer
Background: stereotactic body radiotherapy (SBRT) has emerged as an effective treatment for localized prostate cancer. However, prostate-specific antigen (PSA) kinetics after SBRT has not been well characterized. The objective of the current study is to analyze the rate of PSA decline and PSA nadir following hypofractonated SBRT in localized prostate cancer. Materials and Methods: From 2008...
متن کاملDosimetry analyses comparing high-dose-rate brachytherapy, administered as monotherapy for localized prostate cancer, with stereotactic body radiation therapy simulated using CyberKnife
The purpose of this study was to perform dosimetry analyses comparing high-dose-rate brachytherapy (HDR-BT) with simulated stereotactic body radiotherapy (SBRT). We selected six consecutive patients treated with HDR-BT monotherapy in 2010, and a CyberKnife SBRT plan was simulated for each patient using computed tomography images and the contouring set used in the HDR-BT plan for the actual trea...
متن کاملDose-Escalated Robotic SBRT for Stage I–II Prostate Cancer
Stereotactic body radiotherapy (SBRT) is the precise external delivery of very high-dose radiotherapy to targets in the body, with treatment completed in one to five fractions. SBRT should be an ideal approach for organ-confined prostate cancer because (I) dose-escalation should yield improved rates of cancer control; (II) the unique radiobiology of prostate cancer favors hypofractionation; and...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملProstate-specific antigen kinetics after primary stereotactic body radiation therapy using CyberKnife for localized prostate cancer
PURPOSE To assess prostate-specific antigen (PSA) kinetics and report on the oncologic outcomes for patients with localized prostate cancer treated with stereotactic body radiation therapy (SBRT) using CyberKnife. METHODS We extracted the list and data of 39 patients with clinically localized prostate cancer who had undergone primary SBRT using CyberKnife between January 2008 and December 201...
متن کامل