Spatial decision on allocating automated external defibrillators (AED) in communities by multi-criterion two-step floating catchment area (MC2SFCA)
نویسندگان
چکیده
BACKGROUND The occurrence of out-of-hospital cardiac arrest (OHCA) is a critical life-threatening event which frequently warrants early defibrillation with an automated external defibrillator (AED). The optimization of allocating a limited number of AEDs in various types of communities is challenging. We aimed to propose a two-stage modeling framework including spatial accessibility evaluation and priority ranking to identify the highest gaps between demand and supply for allocating AEDs. METHODS In this study, a total of 6135 OHCA patients were defined as demand, and the existing 476 publicly available AEDs locations and 51 emergency medical service (EMS) stations were defined as supply. To identify the demand for AEDs, Bayesian spatial analysis with the integrated nested Laplace approximation (INLA) method is applied to estimate the composite spatial risks from multiple factors. The population density, proportion of elderly people, and land use classifications are identified as risk factors. Then, the multi-criterion two-step floating catchment area (MC2SFCA) method is used to measure spatial accessibility of AEDs between the spatial risks and the supply of AEDs. Priority ranking is utilized for prioritizing deployment of AEDs among communities because of limited resources. RESULTS Among 6135 OHCA patients, 56.85 % were older than 65 years old, and 79.04 % were in a residential area. The spatial distribution of OHCA incidents was found to be concentrated in the metropolitan area of Kaohsiung City, Taiwan. According to the posterior mean estimated by INLA, the spatial effects including population density and proportion of elderly people, and land use classifications are positively associated with the OHCA incidence. Utilizing the MC2SFCA for spatial accessibility, we found that supply of AEDs is less than demand in most areas, especially in rural areas. Under limited resources, we identify priority places for deploying AEDs based on transportation time to the nearest hospital and population size of the communities. CONCLUSION The proposed method will be beneficial for optimizing resource allocation while considering multiple local risks. The optimized deployment of AEDs can broaden EMS coverage and minimize the problems of the disparity in urban areas and the deficiency in rural areas.
منابع مشابه
Optimal Installation Locations for Automated External Defibrillators in Taipei 7-Eleven Stores: Using GIS and a Genetic Algorithm with a New Stirring Operator
Immediate treatment with an automated external defibrillator (AED) increases out-of-hospital cardiac arrest (OHCA) patient survival potential. While considerable attention has been given to determining optimal public AED locations, spatial and temporal factors such as time of day and distance from emergency medical services (EMSs) are understudied. Here we describe a geocomputational genetic al...
متن کاملCan Hospital Standard Manual Defibrillators Be Replaced By Automatic External Defibrillators: Results On A Simulated Model
Introduction: Although AED (automated external defibrillator) are being placed in many public places, standard manual defibrillator (SMD) still predominates in the hospital setting. Study Objective: Determine differences in time to first shock by residents comparing AED's to SMD's. Methods: Emergency Medicine residents were tested using both AED and SMD separately in simulated cardiac arrests. ...
متن کاملImproving survival from sudden cardiac arrest: the role of the automated external defibrillator.
CONTEXT Sudden cardiac death is a major public health problem in the United States, and improving survival after out-of-hospital cardiac arrest has been the subject of intense study. Early defibrillation has been shown to be critical to improving survival. Use of automated external defibrillators (AEDs) has become an important component of emergency medical systems, and recent advances in AED t...
متن کاملReliability of old and new ventricular fibrillation detection algorithms for automated external defibrillators
BACKGROUND A pivotal component in automated external defibrillators (AEDs) is the detection of ventricular fibrillation by means of appropriate detection algorithms. In scientific literature there exists a wide variety of methods and ideas for handling this task. These algorithms should have a high detection quality, be easily implementable, and work in real time in an AED. Testing of these alg...
متن کاملRecalls and safety alerts affecting automated external defibrillators.
CONTEXT Automated external defibrillators (AEDs) play a key role in the community resuscitation of persons with cardiac arrest and are of proven clinical benefit. Although AEDs are complex medical devices designed to function during life-threatening emergencies, little is known about their reliability. OBJECTIVES To determine the number and rate of AED recalls and safety alerts, to identify t...
متن کامل