Effect of fluoride-containing tubes on accuracy of glucometers.

نویسندگان

  • Hung-Yuan Li
  • Cyue-Huei Hua
  • Yi-Ru Lin
  • Mao-Shin Lin
  • Jung-Nan Wei
چکیده

G lucometers are used to quickly obtain glucose concentrations in the hospital and at home. For quality assurance, the American Diabetes Association recommends periodically comparing the results from glucometers with those from referenced laboratories (1). Usually, measurement using glucometers is done one-by-one by technicians, which is costly regarding manpower. In contrast, measurement using blood analyzers in laboratories saves manpower by analyzing after sufficient samples are collected. Tubes containing glycolytic inhibitors such as sodium fluoride are used to keep the glucose level constant (2). If analyses by glucometers could be done similarly, the laboratory could also save manpower. However, the Food and Drug Administration (FDA) suggests that fluoride should not be used as a preservative for venous specimens when using glucometers (3). Since there was not much explanation in the FDA’s statement, we conducted a study to assess if blood stored in fluoride-containing tubes could be used to measure glucose concentration by glucometers. Six glucometers that allow venous blood to be used were selected: Glucometer Elite (Bayer), Accu-Chek Advantage (Roche), Accu-Chek Go (Roche), AccuChek Active (Roche), Optium (Abbott), and Sure Step (Johnson & Johnson). One new meter was randomly selected from each manufacturer. Venous blood was collected in fluoride-containing tubes (sodium fluoride/K3EDTA; Greiner BioOne VACUETTE North America) from 62 consecutive subjects who had diabetes and were not receiving dialysis. The stored blood was applied to the reagent strip of glucometers in random order. The reference measurements were performed by blood analyzer (Toshiba Medical Systems, Tokyo, Japan) in the laboratory. The regression and correlation coefficients between the values from the reference measurement and each glucometer ranged from 0.898 to 1.366 and from 0.938 to 0.993, respectively. The mean SD of the bias of glucometers, which was calculated as (glucometer reference) 100%/reference, ranged from 5.3 3.7% to 31.5 7.5%. The percentage of bias 5%, as recommended by the American Diabetes Association (1), was low among all glucometers. The most accurate was the Accu-Chek Advantage meter (54.8%), and the others were all under 20%. Alternatively, using criteria by the FDA (bias 20%) (3), the Accu-Chek Advantage, Elite, and Optium meters had 100, 83.9, and 83.9% of values met, respectively, while the others were all under 70%. The error grid analysis showed that all of the measurements from the Accu-Chek Advantage, Elite, and Optium meters lay in zones A and B. Interestingly, these three devices were all amperometric systems, while the others were all photometric systems. However, we could not find supporting evidence from a review of the literature. In conclusion, our study demonstrated that when manpower is a concern, fluoride-containing tubes may be used with certain glucometers with acceptable results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of fluoride additive on alpha-Alumina Formation from Active Alumina

a-Al2O3 is the most important raw material for synthesizing modern ceramics and high alumina refractories. Active Alumina (also known as Hydratable Alumina and r-Al2O3) is a kind of transition alumina which is produced by flash-calcining of Gibbsite at 500-600 oC. In this research, the effect of Ammonium bi-fluoride additive (NH4HF2), on the formation of a-Al2O3 from active alumina was investig...

متن کامل

Effect of Fluoride Gel and Foam on Salivary Fluoride Concentration

Background and Aim: Many studies have shown that various fluoride-containing products can change salivary fluoride concentration. Nowadays, different kinds of topical fluoride gels and foams are used to prevent dental caries. The aim of this study was to evaluate salivary fluoride concentration following the application of 3 different fluoride containing materials at different follow-up interva...

متن کامل

Sodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability

Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond strength (µTBS) over time. Material & Methods: In this experimental study, 36 extracted  third molars were used to evaluate the µTBS of...

متن کامل

The Effect of Topical Iodine and Fluoride Varnish Combination in Preventing Early Childhood Caries: A Pilot Study

 Background: Early Childhood Caries (ECC) in the earliest stage is preventable. The studies indicate oral bacteria play an important role in pathogenesis of dental caries. According to high prevalence of ECC, alternative therapies should be explored in order to reduce the occurrence of it. Aim: This study aims to assess the effectiveness of a product containing Povidone Iodine 10% and Sodium Fl...

متن کامل

Comparing the Effect of Topical Acidulated Phosphate Fluoride on Micro-Hardness of Two Fissure Sealants and One Flowable Composite

  Objective: Probable effect of fluoride containing materials like APF on sealants is very important. The purpose of this study is to assess the effect of frequent application of APF (1.23%) on the surface microhardness of two fissure sealants and one flowable composite.   Methods: In this experimental study, 81 specimens of two fissure sealants and one flowable composite were prepared, using s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes care

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2008