Permeation of multifunctional acrylates through selected protective glove materials.

نویسندگان

  • E P Renard
  • R Goydan
  • T Stolki
چکیده

In support of the Premanufacture Notification (PMN) program of the Environmental Protection Agency's Office of Toxic Substances, the resistance of three glove materials to permeation by multifunctional acrylate compounds was evaluated through a program for the Office of Research and Development. Several recent PMN submissions relate to multifunctional acrylates and essentially no permeation data are available for this class of compounds. To better understand permeation behavior, tests were conducted with trimethylolpropane triacrylate (TMPTA), 1,6-hexanediol diacrylate (HDDA), and two mixtures of HDDA with 2-ethylhexyl acrylate (EHA). Because of the low vapor pressure and low water solubility of these compounds, the tests were conducted by using ASTM Method F739-85 with a silicone rubber sheeting material as the collection medium. Tests were performed at 20 degrees C with butyl, natural, and nitrile rubber glove materials. None of the acrylate compounds nor mixtures was found to permeate the butyl or nitrile rubber under the test conditions. Permeation through the natural rubber was observed in tests with pure HDDA, a 50% HDDA/50% EHA mixture, and a 25% HDDA/75% EHA mixture. TMPTA permeation through the natural rubber was also detected, but only in one of the triplicate tests after the 360-480 min sampling interval. For pure HDDA, the breakthrough detection time was 30-60 min and the steady-state permeation rate was 0.92 micrograms/cm2-min. For the HDDA/EHA mixtures, permeation of both mixture components was detected during the same sampling interval in each test. The breakthrough detection time was 30-60 min for the 50/50 mixture and from 15-30 to 30-60 min for the 25/75 mixture.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a permeation panel to test dermal protective clothing against sprayed coatings.

OBJECTIVES Design, construct, and characterize an apparatus to evaluate dermal protective clothing for resistance to polymerizing materials. Specifically, we evaluated the permeation of the most common glove material used in automotive collision repair (0.10-0.13 mm or 4-5 mil latex) with representative isocyanate-containing clear coats. Our ultimate goal is to make informed recommendations on ...

متن کامل

Resistance of gloves and protective clothing materials to permeation of cytostatic solutions.

OBJECTIVES The objective of the work was to determine the resistance of selected protective clothing and glove materials to permeation of cytostatics such as docetaxel, fluorouracil, and doxorubicin. MATERIAL AND METHODS The following glove materials were used: natural rubber latex (code A), acrylonitrile-butadiene rubber (code B) and chloroprene rubber (code C). In addition, we tested a laye...

متن کامل

Permeation of Herbicidal Dichlobenil From a Casoron Formulation Through Nitrile Gloves

The aim of this study was to measure permeation of the herbicide dichlobenil in Casoron 4G through disposable and chemically protective nitrile gloves using an American Society for Testing and Materials-type permeation cell and a closed-loop system employing two different solvents (hexane and water) and two different challenge situations (aqueous emulsion and solid formulation). Capillary gas c...

متن کامل

Gloves against mineral oils and mechanical hazards: composites of carboxylated acrylonitrile–butadiene rubber latex

Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile-butadiene rubber (XNBR) latex. The obtained materials were characterized by a ...

متن کامل

Permeation tests of glove and clothing materials against sensitizing chemicals using diphenylmethane diisocyanate as an example.

Diphenylmethane diisocyanate (MDI) is a sensitizing chemical that can cause allergic contact dermatitis and asthma. Protective gloves and clothing are necessary to prevent skin exposure. Breakthrough times are used for the selection of chemical protective gloves and clothing. In the EN 374-3:2003 European standard, breakthrough time is defined as the time in which the permeation reaches the rat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American Industrial Hygiene Association journal

دوره 53 2  شماره 

صفحات  -

تاریخ انتشار 1992