Molecular epidemiology of Rhodococcus equi of intermediate virulence isolated from patients with and without acquired immune deficiency syndrome in Chiang Mai, Thailand.

نویسندگان

  • Shinji Takai
  • Prasit Tharavichitkul
  • Piyawan Takarn
  • Banyoung Khantawa
  • Mami Tamura
  • Azusa Tsukamoto
  • Saki Takayama
  • Noriko Yamatoda
  • Ayumi Kimura
  • Yukako Sasaki
  • Tsutomu Kakuda
  • Shiro Tsubaki
  • Niwat Maneekarn
  • Thira Sirisanthana
  • Teruo Kirikae
چکیده

We investigated the prevalence of virulent Rhodococcus equi in clinical isolates from 69 sporadic cases (60 men, 8 women, and 1 patient of unknown sex) in Chiang Mai, Thailand, between 1993 and 2001. Fifty were human immunodeficiency virus (HIV) positive, 3 were HIV negative, and HIV status was unknown for 16. Fifty-two (75%) of 69 isolates were strains of intermediate virulence that contained the virulence-associated 20-kDa antigen, and 17 isolates (25%) were avirulent. No virulent strains with the virulence-associated 15-17-kDa antigens were identified. R. equi was isolated from HIV-positive patients' houses and those of their neighbors: avirulent strains were widespread, but only 1 strain of intermediate virulence was isolated. R. equi strains of intermediate virulence were isolated from 4 (0.8%) of 500 submaxillary lymph nodes from apparently healthy pigs in Chiang Mai. The routes of R. equi acquisition should be investigated from the viewpoint of zoonosis and public health.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-pulmonary Rhodococcus equi infections in patients with acquired immune deficiency syndrome (AIDS).

Rhodococcus equi, formerly known as Corynebacterium equi, was isolated repeatedly from the blood of two patients with the acquired immune deficiency syndrome (AIDS). Neither of the patients had pneumonia while they were bacteraemic, whereas pneumonia has been present in all previously reported cases of human infection with R equi. One of our patients had diarrhoea and the organism was isolated ...

متن کامل

Comparative study of Master's Community Health Nursing in Iran with Chiang Mai University of Thailand

Introduction: The main mission of Nursing Colleges and Centers is to improve the learning and learning of learners during training. Regarding the performance of other countries, this study also aimed to compare the postgraduate program of Master of community Health Nursing in Iran with Chiang Mai University in Thailand.This study aimed to compare the Master's degree program of community health ...

متن کامل

Knowledge, Attitude, Practice and Acceptance of COVID-19 Vaccine among Elderly in Chiang Mai, Thailand

Aims: This study determined the knowledge, attitudes, and practices regarding COVID-19 and assessed the acceptance of the COVID-19 vaccine among the elderly in Chiang Mai, Thailand. Instrument & Methods: From February to May 2021, a cross-sectional study was conducted among 450 elderly 60 years old and above who lived in Chiang Mai Municipality. The questionnaire collected demographic characte...

متن کامل

Effect of low dose X-ray on membrane fluidity of thalassemic red blood cells

Background: Chest X-ray is one of the examinations required for an annual health checkup. The interaction of radiation to the medium produces free radicals, which consequently causes biological changes either structural or properties of the cells. Whether the radiation from Chest X-ray upright technique affects the plasma membrane fluidity of thalassemic red blood cells (RBCs) is still unclear....

متن کامل

Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays

Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of infectious diseases

دوره 188 11  شماره 

صفحات  -

تاریخ انتشار 2003