A Large Response Range Reflectometric Urea Biosensor Made from Silica-Gel Nanoparticles
نویسندگان
چکیده
A new silica-gel nanospheres (SiO2NPs) composition was formulated, followed by biochemical surface functionalization to examine its potential in urea biosensor development. The SiO2NPs were basically synthesized based on sol-gel chemistry using a modified Stober method. The SiO2NPs surfaces were modified with amine (-NH2) functional groups for urease immobilization in the presence of glutaric acid (GA) cross-linker. The chromoionophore pH-sensitive dye ETH 5294 was physically adsorbed on the functionalized SiO2NPs as pH transducer. The immobilized urease determined urea concentration reflectometrically based on the colour change of the immobilized chromoionophore as a result of the enzymatic hydrolysis of urea. The pH changes on the biosensor due to the catalytic enzyme reaction of immobilized urease were found to correlate with the urea concentrations over a linear response range of 50-500 mM (R2 = 0.96) with a detection limit of 10 mM urea. The biosensor response time was 9 min with reproducibility of less than 10% relative standard deviation (RSD). This optical urea biosensor did not show interferences by Na+, K+, Mg2+ and NH4+ ions. The biosensor performance has been validated using urine samples in comparison with a non-enzymatic method based on the use of p-dimethylaminobenzaldehyde (DMAB) reagent and demonstrated a good correlation between the two different methods (R2 = 0.996 and regression slope of 1.0307). The SiO2NPs-based reflectometric urea biosensor showed improved dynamic linear response range when compared to other nanoparticle-based optical urea biosensors.
منابع مشابه
A Urea Biosensor from Stacked Sol-Gel Films with Immobilized Nile Blue Chromoionophore and Urease Enzyme
An optical urea biosensor was fabricated by stacking several layers of sol-gelfilms. The stacking of the sol-gel films allowed the immobilization of a Nile Bluechromoionophore (ETH 5294) and urease enzyme separately without the need of anychemical attachment procedure. The absorbance response of the biosensor was monitoredat 550 nm, i.e. the deprotonation of the chromoionophore. This multi-laye...
متن کاملPlatinum nanoparticles-doped sol-gel/carbon nanotubes composite electrochemical sensors and biosensors.
Platinum nanoparticle-doped sol-gel solution is prepared and used as a binder for multi-walled carbon nanotubes (CNT) for the fabrication of electrochemical sensors. Amine group containing sol-gel solution is selected to utilize the affinity of -NH(2) groups toward metal nanoparticles for stabilization the nanoparticles in solution. The resulting CNT-silicate material brings new capabilities fo...
متن کاملLayer-by-Layer Self-Assembling Gold Nanorods and Glucose Oxidase onto Carbon Nanotubes Functionalized Sol-Gel Matrix for an Amperometric Glucose Biosensor
A novel amperometric glucose biosensor was fabricated by layer-by-layer self-assembly of gold nanorods (AuNRs) and glucose oxidase (GOD) onto single-walled carbon nanotubes (SWCNTs)-functionalized three-dimensional sol-gel matrix. A thiolated aqueous silica sol containing SWCNTs was first assembled on the surface of a cleaned Au electrode, and then the alternate self-assembly of AuNRs and GOD w...
متن کاملSynthesis and Characterizations of Silica Nanoparticles by a New Sol-Gel Method
Silica nanoparticles were synthesized by chemical methods from tetraethylorthosilicate (TEOS), polyethylene glycol 5% and hydrochloric acid 0.001 N. The sol-gel process was applied for the preparation of nano silica gel. This method is hydrolysis and condensation reactions of TEOS as precursor of silica. The optimal synthesis conditions for the preparation of silica nanoparticles were obtained ...
متن کاملSol–gel-derived thick-film conductometric biosensor for urea determination in serum
A conductometric urea biosensor based on sol–gel-immobilized urease on a screen-printed inter-digitated array (IDA) electrode has been developed. The screen-printed thick-film IDA electrode has proven to be an excellent conductometric transducer in which the admittance signal was dominated by the conductance signal and the resulting dynamic range was wide enough to be employed for the construct...
متن کامل