An evaluation of the use of concentrators for domiciliary oxygen supply for less than 8 h day-1.
نویسندگان
چکیده
Since their introduction in 1985, oxygen concentrators have only been recommended when domiciliary oxygen is used for over 8 h day-1. Subsequent changes in the prices of oxygen merit a reappraisal of the prescribing of concentrators and cylinders when oxygen is used for less than 8 h day-1. Twenty-six patients in two health districts who used oxygen for less than 8 h day-1 completed a crossover study in which each group received oxygen from each source for consecutive 3-month periods. The patients were visited at home before and during the study, and on each visit they completed a questionnaire asking about their use of oxygen, how acceptable they found the two sources and about several dimensions of their quality of life. The theoretical minimum cost of cylinder supply, the actual cost of cylinder supply and the average concentrator costs were assessed. The patients found the concentrators to be more acceptable, more useful and less obtrusive than cylinders. They used more oxygen in more rooms of the home during treatment with concentrators, and there were improvements in the quality-of-life measurements. The costing information showed that, both in theory and in practice, oxygen concentrators are cheaper than cylinders when oxygen is used for more than about 1.4 h day-1. These results suggest that the provisions for the supply of domiciliary oxygen should be reviewed and that concentrators should be recommended for patients who use more than around 1.4 h day-1.
منابع مشابه
Insufficient oxygen concentration obtained at domiciliary controls of eighteen concentrators.
The oxygen concentration (O2%) produced by 12 type A concentrators, with a working time of 28-18,099 h, and 6 type B concentrators, with a working time of 0-3,033 h, was measured over a 12 month period in the user's home, at a flow rate of 2 l.min-1. One hundred and two measurements of O2% (mean 82.9), made at least once monthly by a visiting nurse, showed that type A concentrators were usually...
متن کاملTechnical and clinical assessment of oxygen concentrators.
One membrane oxygen enricher (Oxygen Enrichment Company OE-4E) and four molecular sieve (MS) concentrators (Mountain Medical Econo2, De Vilbiss MINI DeVO2, Cryogenic Roomate III, and Mountain Medical Mini O2) have been studied to assess technical and clinical performance. During four weeks of continuous operation at a flow rate of 2 l min-1 (6 l min-1 for OE-4E) consistent oxygen levels were de...
متن کاملDomiciliary oxygen concentrators in anaesthesia: preoxygenation techniques and inspired oxygen concentrations.
A conventional preoxygenation technique was compared in two volunteers with two techniques based on a drawover breathing system supplied with oxygen enriched air from a Devilbiss Mini VO2 domiciliary oxygen concentrator. Breathing from a 20-litre bag, filled previously at 2 litre min-1 from the concentrator was as effective as the conventional technique (PaO2 73.2 kPa). Supplying 4 litre min-1 ...
متن کاملClinical experience with the oxygen concentrator.
The oxygen concentrator is an accepted means of delivery of long term domiciliary oxygen treatment. Conditions of use, however, need to be carefully defined. Fourteen concentrators were used for one year by patients with hypoxaemic chronic obstructive airways disease, and mechanical reliability, patient compliance with a regimen of 15 hours' use a day, smoking habits, and variation in arterial ...
متن کاملOxygen supplies for hospitals in Papua New Guinea: a comparison of the feasibility and cost-effectiveness of methods for different settings.
Oxygen therapy is essential in all wards, emergency departments and operating theatres of hospitals at all levels, and oxygen is life-saving. In Papua New Guinea (PNG), an effective oxygen system that improved the detection and treatment of hypoxaemia in provincial and district hospitals reduced death rates from pneumonia in children by as much as 35%. The methods for providing oxygen in PNG ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory medicine
دوره 92 2 شماره
صفحات -
تاریخ انتشار 1998