Quality initiative: Quantifying and reducing dose in multiphase liver CT: Eliminating the nonenhanced study and using conscientious Z-creep
نویسندگان
چکیده
The use of computed tomography (CT) for evaluation of liver disease has increased dramatically at our tertiary care center due to increased hepatology referrals. We sought to decrease the radiation dose associated with multiphase liver CT studies while maintaining a high degree of diagnostic accuracy. We found that by eliminating the nonenhanced acquisition and adjusting the imaging field of view to include the liver-containing abdomen only-simply by manipulation of patient-specific imaging parameters-we achieved a 30% reduction in dose.
منابع مشابه
Optimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study
Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...
متن کاملQuantitative Image Quality Comparison of Reduced- and Standard-Dose Dual-Energy Multiphase Chest, Abdomen, and Pelvis CT
We present a new image quality assessment method for determining whether reducing radiation dose impairs the image quality of computed tomography (CT) in qualitative and quantitative clinical analyses tasks. In this Institutional Review Board-exempt study, we conducted a review of 50 patients (male, 22; female, 28) who underwent reduced-dose CT scanning on the first follow-up after standard-dos...
متن کاملApplication of Different methods for Reducing Radiation Dose to Breast during MDCT
The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...
متن کاملComparison of entrance skin dose in the hip region in the imaging of the lower extremity by CT scan and EOS
Introduction: Increasing in refer to computed tomography (CT-scan) imaging causes to increase in cumulative dose. Stereoradiography (EOS) is an X-ray imaging technology that, by eliminating scattering radiation, reduces patient's absorption dose and improves image quality. Materials and Methods: This cross-sectional study was carried out in a hosp...
متن کاملUsefulness of nanoparticles to making shield and protection of sensitive organs in chest CT scan test
Introduction: Recently, the use of nanoparticles has increased for many purpose in medicine. One of these is using the nano particles in shields structure to protect sensitive organs such as breast which placed inside the field of chest CT scan and receives high dose. The aim of this study was the use of nano Bi2O3 to making shield for protection breast in chest CT examination ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -