The addition of a membrane oxygenator to a ventricular assist device in a patient with acute respiratory distress syndrome.

نویسندگان

  • Peter Betit
  • Gregory S Matte
  • Robert Howe
  • Peter Iudiciani
  • Cindy Barrett
  • Ravi Thiagarajan
  • Francis Fynn-Thompson
چکیده

A 12-year-old boy with Marfan's syndrome required a biventricular assist device (VAD) after an aortic root replacement. The patient developed acute respiratory distress syndrome and required escalating ventilator support. We hypothesized that the addition of a membrane oxygenator in series with the assist device would improve gas exchange and allow for a more lung-protective ventilator approach. A membrane oxygenator was placed in series with the right VAD resulting in a blood path of right atrium to VAD to oxygenator to pulmonary artery. Circuit function was gauged by monitoring flow and oxygenator pressures and periodic circuit inspections and oxygenator blood gases. Heparin was titrated to maintain unfractionated antifactor Xa levels of .3-.7 IU/mL and partial thromboplastin time of 60-80 seconds. The initial sweep gas supplying the oxygenator was 5 L/min at an F1O2 of 1.0, which achieved a pH > 7.40 and a PF ratio > 250. The pre- and post-oxygenator pressures were 55-60 mmHg and 45-50 mmHg, respectively, and the measured flow at the oxygenator outlet was 2.0-2.2 L/min. The patient was changed from high-frequency oscillatory ventilation to pressure-controlled synchronized intermittent ventilation with pH maintained at 7.35-7.40 and PF ratio > 250. Paralytics were discontinued and the patient's neurologic condition was deemed intact. The patient hemorrhaged after a sternal closure and required transfusions and antifibrinolytics that led to thrombus in the membrane and membrane circuitry, which were replaced without incident. The patient's respiratory status remained stable; however, his overall condition worsened as a result of additional organ dysfunction and septicemia, and he did not survive. The addition of a membrane oxygenator to a VAD is feasible and supplements gas exchange permitting the use of more lung protective ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Respiratory Distress Syndrome in a Patient With Suspected Influenza: A Case Report

Acute Respiratory Distress Syndrome (ARDS) is a clinical syndrome consisting of tachypnea, refractory hypoxemia, and diffuse opacities on chest radiographs after infection or trauma which ultimately leads to respiratory failure. The principles of treatment are based on patient care in ICU, mechanical ventilation and medical treatments. By using lower plateau, less tidal volume, higher positive ...

متن کامل

Hypersensitivity Reaction and Acute Respiratory Distress Syndrome in Pyrethroid Poisoning and Role of Steroid Therapy

Background: Pyrethroids are generally of low toxicity to humans, but in suicidal poisonings which are usually associated with ingestion of high doses, they lead to severe systemic effects. Case Report: A 30-year old woman presented to emergency department with a history of intentional ingestion of about 15 mL of prallethrin around 3 days earlier. She complained of shortness of breath along with...

متن کامل

Pii: S1010-7940(00)00389-4

Objective: Long-term extracorporeal lung assist is limited by a signi®cant mechanical blood trauma resulting in bleeding and hemolysis. To reduce the drawbacks of extracorporeal lung assist a new technique has been developed, by which the driving force for the extracorporeal circuit derives from the patients arterio-venous pressure gradient (pumpless extracorporeal lung assist). The aim of this...

متن کامل

Rhabdomyolysis and Acute Respiratory Distress Syndrome Secondary to Multiple Wasp Stings

Background: Wasp stings usually cause local reactions such as itching, urticaria, angioedema and anaphylaxis. Life-threatening complications following multiple wasp stings are relatively rare and unexpected. However, rhabdomyolysis and acute respiratory distress syndrome following wasp stings are possible. Case presentation: A middle-aged male worker was stung by a swarm of wasps all over his b...

متن کامل

Validity of Spo2/Fio2 Ratio in Detection of Acute Lung Injury and Acute Respiratory Distress Syndrome

Introduction:  One ofdiagnostic criteria for Acute Lung Injury and Acute Respiratory Distress Syndrome is  pao2/fio2 (PF) ratio 300 for ALI or 200 for ARDS. This criteria requires invasive arterial sampling. Measurement of Spo2/Fio2 (SF) ratio by pulseoximetry may be a reliable non invasive alternative to the PF ratio.   Methods and Materials: In a cross sectional study we enrolled 105 sample o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 43 4  شماره 

صفحات  -

تاریخ انتشار 2011