Venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator lead implantation.

نویسندگان

  • Xu Duan
  • Feng Ling
  • Yun Shen
  • Jun Yang
  • Hai-ying Xu
چکیده

AIMS Contrast-guided axillary vein puncture is commonly used for pacemaker or defibrillator lead implantation. Venous spasm during contrast-guided axillary vein puncture has been reported rarely. We investigated the incidence of venous spasm during contrast-guided axillary vein puncture and the impact of venous spasm on axillary vein puncture. METHODS AND RESULTS Seventy-four consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantation were included in the study. The puncture was guided by fluoroscopy and the venogram of axillary vein. After the success of puncture, the venography was taken again. When the puncture could not be successful up to 3 min, the second venography was taken and the puncture was guided by the second venogram. The degree of venous spasm was evaluated by the reduction in the lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in the lumen calibre of 50-90 and ≥ 90%, respectively. The success rate of axillary vein puncture within 3 min was 87.8%, and the total success rate was 95.9%. Mild venous spasm occurred in 22 patients (29.7%) and severe venous spasm occurred in 6 patients (8.1%). Severe venous spasm occurred in all the three patients with a failed puncture. Severe venous spasm was independently negatively correlated with both success rate within 3 min and total success rate. CONCLUSION Venous spasm is not a rare phenomenon during the contrast-guided puncture of axillary vein and it has an important negative impact on the puncture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A safe and effective method for pacemaker implantation in children Axillary vein puncture for device implantation and use of 4F catheter- delivered pacing leads in children

Background: Contrast-guided axillary vein puncture has gained popularity for pacemaker and implantable cardioverter defibrillator (ICD) implantation in adults owing to its low risk profile, and could be an alternative to subclavian vein puncture, which is commonly performed in children. The Medtronic 3830 lead is a 4.1F lumenless catheter-delivered lead which may be particularly well-suited for...

متن کامل

Venous spasm during pacemaker implantation.

A 75-years-old female presented with dyspnea and syncope. Electrocardiogram revealed atrial fibrillation and complete atrioventricular block. She was therefore listed for pacemaker implantation on the next day. Initial attempt at venous access was left axillary vein. A venogram showed good venous anatomy (Fig. 1a). Several attempts to puncture axillary vein were made. However, there was no good...

متن کامل

Axillary vein puncture without contrast venography for pacemaker and defibrillator leads implantation.

BACKGROUND Axillary vein puncture has been demonstrated to be an effective method for pacemaker and defibrillator leads implantation, without the complications encountered with the standard intrathoracic approach. OBJECTIVE Different techniques have been adopted for the cannulation of the axillary vein. We report our experience using the outer edge of the first rib below the inferior border o...

متن کامل

Venous variations in neck region: cephalic vein

The cephalic vein, defined as the vein originating in the radial end of the dorsal venous arch, crosses superficial to the anatomical snuffbox and travels upward along the anterior border of the brachioradialis muscle in the forearm [1,2]. It ascends lateral to biceps and between pectoralis major and deltoid muscles, and passes through the infraclavicular fossa, and drains into the axillary vei...

متن کامل

Hemoptysis After Subclavian Vein Puncture for Pacemaker Implantation: Importance of Wire-Guided Venous Puncture

We report a case of hemoptysis occurring after subclavian vein puncture for pacemaker implantation. Hemoptysis related to injury of lung parenchyma is a rare complication of subclavian vein access and is usually self limited, but can affect prognosis in critically ill patients. Venogram-guided or even better wire-guided venous puncture allow safe access to the subclavian vein in difficult cases...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 14 7  شماره 

صفحات  -

تاریخ انتشار 2012