Enhanced Dissolution of Liquid Microdroplets in the Extensional Creeping Flow of a Hydrodynamic Trap.
نویسندگان
چکیده
A novel noncontact technique based on hydrodynamic trapping is presented to study the dissolution of freely suspended liquid microdroplets into a second immiscible phase in a simple extensional creeping flow. Benzyl benzoate (BB) and n-decanol microdroplets are individually trapped at the stagnation point of a planar extensional flow, and dissolution of single microdroplets into an aqueous solution containing surfactant is characterized at different flow rates. The experimental dissolution curves are compared to two models: (i) the Epstein-Plesset (EP) model which considers only diffusive mass transfer, and (ii) the Zhang-Yang-Mao (ZYM) model which considers both diffusive and convective mass transfer in the presence of extensional creeping flow. The EP model significantly underpredicts the experimentally determined dissolution rates for all experiments. In contrast, very good agreement is observed between the experimental dissolution curves and the ZYM model when the saturation concentration of the microdroplet liquid (cs) is used as the only fitting parameter. Experiments with BB microdroplets at low surfactant concentration (10 μM) reveal cs values very similar to that reported in the literature. In contrast, experiments with BB and n-decanol microdroplets at 10 mM surfactant concentration, higher than the critical micelle concentration (CMC) of 5 mM, show further enhancements in microdroplet dissolution rates due to micellar solubilization. The presented method accurately tests the dissolution of single microdroplets into a second immiscible phase in extensional creeping flow and has potential for applications such as separation processes, food dispersion, and drug development/design.
منابع مشابه
Experimental and Computational Study on Hydrodynamic of a Downscaled Mini Vessel USP Dissolution Test Apparatus II
Although not listed on the United States Pharmacopeia (USP), like standard USP 2, small volume USP 2 dissolution apparatus has gained a great deal of attention, especially for cases where small amount of drug product is available for testing in research and design step or evaluations are to be made on a tablet containing trace amounts of the active pharmaceutical ingredient. In this work, first...
متن کاملFluid-structure interaction in deformable microchannels
Related Articles High frequency microbubble-switched oscillations modulated by microfluidic transistors Appl. Phys. Lett. 101, 073509 (2012) Convenient quantification of methanol concentration detection utilizing an integrated microfluidic chip Biomicrofluidics 6, 034111 (2012) Giant augmentations in electro-hydro-dynamic energy conversion efficiencies of nanofluidic devices using viscoelastic ...
متن کاملNumerical simulation of hydrodynamic properties of Alex type gliders
Simulation of an underwater glider to investigate the effect of angle of attack on the hydrodynamic coefficients such as lift, drag, and torque. Due to the vital role of these coefficients in designing the controllers of a glider and to obtain an accurate result, this simulation has been studied at a range of operating velocities. The total length of the underwater glider with two wings is 900 ...
متن کاملEnhanced Predictions of Tides and Surges through Data Assimilation (TECHNICAL NOTE)
The regional waters in Singapore Strait are characterized by complex hydrodynamic phenomena as a result of the combined effect of three large water bodies viz. the South China Sea, the Andaman Sea, and the Java Sea. This leads to anomalies in water levels and generates residual currents. Numerical hydrodynamic models are generally used for predicting water levels in the ocean and seas. But thei...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Langmuir : the ACS journal of surfaces and colloids
دوره 32 37 شماره
صفحات -
تاریخ انتشار 2016