Neutron cross-sections and kerma values for carbon, nitrogen and oxygen from 20 to 50 MeV.
نویسنده
چکیده
The advent of high energy neutron radiotherapy will require the neutron cross-section data and kerma factors for elements of biomedical importance to be extended up to and possibly above 50 MeV. Nuclear model calculations have been employed to produce a set of neutron cross-sections for C, N and O from 20 to 50 MeV. The strategy employed involves the optical model fitting of experimental total cross-sections to produce elastic and non-elastic cross-sections. The non-elastic cross-section is then used to normalise the individual reaction cross-sections and charged particle spectra produced by the statistical model of level densities. Kerma values are obtained from charged particle and recoil nucleus spectra. A comparison is made with other kerma calculations, based on the intranuclear cascade-evaporation model, which are consistently lower than the results presented in this paper.
منابع مشابه
A calibration method for realistic neutron dosimetry in radiobiological experiments assisted by MCNP simulation
Many studies on biological effects of neutrons involve dose responses of neutrons, which rely on accurately determined absorbed doses in the irradiated cells or living organisms. Absorbed doses are difficult to measure, and are commonly surrogated with doses measured using separate detectors. The present work describes the determination of doses absorbed in the cell layer underneath a medium co...
متن کاملResponse functions for computing absorbed dose to skeletal tissues from neutron irradiation.
Spongiosa in the adult human skeleton consists of three tissues-active marrow (AM), inactive marrow (IM) and trabecularized mineral bone (TB). AM is considered to be the target tissue for assessment of both long-term leukemia risk and acute marrow toxicity following radiation exposure. The total shallow marrow (TM(50)), defined as all tissues lying within the first 50 µm of the bone surfaces, i...
متن کاملCompare charged and uncharged particles leakage of plasma focus for medical radioisotopes production
In this study, to calculate the radioactivity of radioisotopes such as 11C, 15O, 18F and 123,124I in a focus plasma device for the production of medical radioisotopes, the particles of neutrons and protons with cubic targets of Nitrogen, Xenon, Carbon and a solid natural Boron is used. Particles energy are at the input of the program from 1MeV to 10MeV. Also, the total yield coefficient is cons...
متن کاملuc l - ex / 0 50 10 14 v 2 1 4 Fe b 20 06 Light - ion production in the interaction of 96 MeV neutrons with oxygen
Double-differential cross sections for light-ion (p, d, t, He and α) production in oxygen induced by 96 MeV neutrons are reported. Energy spectra are measured at eight laboratory angles from 20◦ to 160◦ in steps of 20◦. Procedures for data taking and data reduction are presented. Deduced energy-differential and production cross sections are reported. Experimental cross sections are compared to ...
متن کاملEstimation of neutron kerma in biological tissue containing boron and gadolinium compounds for neutron capture therapy
where kD=1.602 10 Gy⋅g/MeV — energy conversion factor from MeV to Gy×g, (obtained from the known ratio: 1 MeV=1.602 10 J); Е – neutron energy, MeV; Ф(r,Е) dE – neutron flux in the point r on the energy interval dE, neutron/cm/s: ni – atomic density of the i-th nuclide of the medium, atom/cm; σij(E) –microscopic cross-section of reaction j at interaction of a neutron with energy Е on the i-th nu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 25 4 شماره
صفحات -
تاریخ انتشار 1980