Assessment of the sterility of long-term cardiac catheterization using the thermodilution Swan-Ganz catheter.

نویسندگان

  • J J Applefeld
  • T E Caruthers
  • D J Reno
  • J M Civetta
چکیده

Fifty-seven patients requiring catheterization with a thermodilution Swan-Ganz catheter in the surgical intensive care unit were prospectively studied to determine the incidence and significance of positive pulmonary arterial blood cultures. Nonseptic (group 1) and septic (group 2) patients were identified, with subdivision of the groups into A and B classes contingent upon a negative or positive pulmonary arterial blood culture respectively. In the nonseptic group, there were no positive blood cultures, provided there was only one catheterization (Swan-Ganz), less than three repositionings of the catheter, and discontinuation of the catheterization within 72 hours after insertion. Although the septic group followed this pattern, 25 percent incidence of positive pulmonary arterial blood cultures was present within the 72-hour period. We believe that the thermodilution Swan-Ganz catheter is presently a valuable clinical tool and does not predispose the patient to an excessive infectious disease risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inadvertent fracture during the attempted removal of entrapped Swan-Ganz catheter.

Dear Editor, Pulmonary artery catheter is widely used in cardiovascular surgical practice. Various complications of the Swan-Ganz catheter during insertion, its long-term placement, or removal are well known since its introduction.1-5 Herein, we report a case of the inadvertent fracture of an entrapped Swan-Ganz catheter during its attempted removal with moderate external traction. A 36-year-ol...

متن کامل

Measurement of cardiac output in ventricular rupture following acute myocardial infarction--pulmonary artery catheter vs transpulmonary thermodilution--a case report.

We compared the cardiac output measured by the transpulmonary aortic single indicator thermodilution method with that by the pulmonary artery catheterization in a patient with ventricular septal rupture after acute myocardial infarction. Though the former cardiac output was lower than the latter, in the presence of the ventricular septal rupture, the cardiac outputs were equal after the rupture...

متن کامل

Hepatic vein obstruction due to Swan-Ganz catheter placement.

Complications from Swan-Ganz catheters during insertion, long-term placement, or removal have been known since its development. I describe the unusual presentation of a pacing Swan-Ganz catheter mispositioned into the hepatic vein producing vascular obstruction, yet with adequate cardiac pacing.

متن کامل

Sterility and repositioning of the Swan-Ganz catheter.

TO me eomm m Communications for this section wIll be published as space and priorities permit. The comments should not exceed 500 words in length, with a maximum of five references; one figure or table can be printed. Exceptions may occur under particular circumstances. Contributions may Include comments on articles published in this periodical, or they may be reports of unique educational char...

متن کامل

Extravascular lung water measurements and hemodynamic monitoring in the critically ill: bedside alternatives to the pulmonary artery catheter.

The recently completed Fluid and Catheter Treatment Trial conducted by the National Institutes of Health ARDSNetwork casts doubt on the value of routine pulmonary artery catheterization for hemodynamic management of the critically ill. Several alternatives are available, and, in this review, we evaluate the theoretical, validation, and empirical databases for two of these: transpulmonary thermo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 74 4  شماره 

صفحات  -

تاریخ انتشار 1978